9.10 Gas specification, The Netherlands
C4 GB/GS
Gas type
Natural gas 2H
(E)
Natural gas
2K**
Propane 3P Liquefied gas
3B/P
Standard test gas, code G20 G25.3 G31 G30/G31
Operating materials
Natural gas, liquid gas x x x x
Gas supply values
Gas pipe connection R 3/4" R 3/4" R 3/4" R 3/4"
Supply flow pressure [mbar] 20 (17 - 25) 25 (20 - 30) 29/37/50 (25 -
57.5)
29/37/50 (25 -
57.5)
Gas data (as per CE) at 15 °C and 1013 mbar dry
Lower Wobbe Index W
i
[MJ/m
3
]
45.7
(36.8 - 49.6)
38.5
(37.2 - 38.9)
70.7
(68.1 - 70.7)
80.6
(68.1 - 80.6)
Upper Wobbe Index W
S
[MJ/m
3
]
50.7
(40.9 - 54.7)
42.7
(41.2 - 43.0)
76.8
(72.9 - 76.8)
87.3
(72.9 - 87.3)
Lower calorific value H
i
[MJ/m
3
]
34 29.9 88 116.1
[MJ/kg] - - 46.3 45.7
Higher calorific value H
S
[MJ/m
3
]
37.8 33.2 95.7 125.8
[MJ/kg] - - 50.4 49.5
Exhaust gas extraction system
Air ventilation system with safe-
ty shutdown
mandatory mandatory mandatory mandatory
Exhaust gas values
CO
2
[%] 9.3 - 9.5 9.1 - 9.3 10.8 - 11.2 12.8 - 13.3
CO [ppm] < 500 < 500 < 500 < 500
**Dit toestel is afgesteld voor de toestelcategorie K (I2K) en is geschikt voor het gebruik van G en G+ distributiegassen
volgens de specificaties zoals die zijn weergegeven in de NT
A 8837:2012 Annex D met een Wobbe‑index van 43,46 – 45,3
MJ/m
3
(droog, 0 °C, bovenwaarde) of 41,23 – 42,98 (droog, 15 °C, bovenwaarde).
Dit toestel kan daarnaast worden omgebouwd en/of opnieuw worden afgeregeld voor de toestelcategorie E (I2E). Dit houdt
derhalve in dat het toestel: “geschikt is voor G+‑gas en H‑gas, dan wel aantoonbaar geschikt is voor G+‑gas en aantoon-
baar geschikt is te maken voor H‑gas” in de zin van het “Besluit van 10 mei 2016 tot wijziging van het Besluit gastoestell-
en….”
9 Technical data