9.6 Electrical supply, Korea
C4 EB/ES (single-phase FC)
12.20 20.10 20.20
3~ 220 V 60 Hz (3/PE)
Rated power consumption [kW] 30.6 35.3 61.1
Convection power [kW] 30.2 34.6 60.4
Steam power (EB only) [kW] 28.6 28.6 36.5
Motor power [kW] 0.35 0.7 0.7
Rated current [A] 80.3 92.6 160.3
Fuse rating [A] 100 100 160
Residual current [mA] - - -
Protective earth current [mA] - - -
Recommended conductor cross-section for wires laid uncovered in air up
to 5 m in length.
[mm
2
]
4G35 4G35 4G70
Residual-current device Type A/B A/B A/B
3N~ 380V 60Hz (3/N/PE)
Rated power consumption [kW] 30.5 35.1 60.7
Convection power [kW] 30.1 34.4 60.0
Steam power (EB only) [kW] 28.5 28.5 36.3
Motor power [kW] 0.35 0.7 0.7
Rated current [A] 46.3 53.3 92.2
Fuse rating [A] 50 63 100
Residual current [mA] ~7.5 ~16.5 ~16.5
Protective earth current [mA] ~7.5 ~16.5 ~16.5
Recommended conductor cross-section for wires laid uncovered in air up
to 5 m in length.
[mm
2
]
5G16 5G16 5G35
Residual-current device Type A/B A/B A/B
9 Technical data
Installation manual 81

Table of Contents