9.14 Gas consumption
C4 GB/GS
12.20 20.10 20.20
Australia, New Zealand
Natural gas (AUS/NZL)
[m
3
/h]
3.0 4.3 6.1
Propane (AUS/NZL)
[m
3
/h]
2.4 3.2 4.6
G30/G31: Propane 3P / liquefied gas 3B/P [kg/h] 2.4 3.4 4.8
Japan
Natural gas 13A (JPN)
[m
3
/h]
2.2 2.9 4.4
Propane (JPN) [kg/h] 2.1 2.9 4.2
Korea
LNG: Natural gas 13A (KOR) [m3/h] 2.5 3.4 5.3
LPG: Propane (KOR) [kg/h] 2.1 3.0 4.5
The Netherlands
G20: Natural gas 2H (E)
[m
3
/h]
3.3 4.2 6.6
G25.3: Natural gas 2K
[m
3
/h]
3.4 4.5 6.8
G30/G31: Propane 3P / liquefied gas 3B/P [kg/h] 2.4 3.4 4.8
Other
G20: Natural gas 2H (E)
[m
3
/h]
3.3 4.2 6.6
G25: Natural gas 2L (LL)
[m
3
/h]
3.8 4.9 7.6
G30/G31: Propane 3P / liquefied gas 3B/P [kg/h] 2.4 3.4 4.8
9.15 Exhaust gas output rate
C4 GB/GS
12.20 20.10 20.20
Air consumption for combustion
[m
3
/h]
68 88 136
Exhaust gas output rate
[m
3
/h]
143 185 286
9 Technical data