Pro-EC44 2-Loop Graphical Profile Controller & Recorder
Pro-EC44 Product Manual - 59540-2 September 2014 Page 142
Plug-in Module Slot 3 Parameters
Parameter Name & Register Address
Integer Int +1 Float Access Values & Descriptions
Plug-in Module 3 Type Value Module Fitted In Slot 3
Dec 2192 18576 37152
RO
0 None Fitted
Hex 0890 4890 9120
1 Single Relay
2 Single SSR Driver
3
Error (invalid module for this slot)
8 Triac
9 Dual Relay
10 Dual SSR Driver
11 24VDC Transmitter PSU
255
Error (unrecognised module)
Output 3 or 3A Status Value Output 3 or 3A Status
Dec 2194 18578 37156
RO
0 Inactive
Hex 0892 4892 9124
1 Active
Output 3B Status Value Output 3B Status
Dec 2195 18579 37158
RO
0 Inactive
Hex 0893 4893 9126
1 Active
Digital Output 3 Latch Enable Value Output 3 or 3A Enable / Disable Latching
Dec 2197 18581 37162
RW
0 Disabled
Hex 0895 4895 912A
1 Enabled
Digital Output 3 Clear Latch Value Output 3 or 3A Latch Clear
Dec 2198 18582 37164
RW
0 Do Nothing
Hex 0896 4896 912C
1 Clear Latch
Digital Output 3 Latch State Value Output 3 or 3A Latch State
Dec 2199 18583 37166
RO
0 Unlatched
Hex 0897 4897 912E
1 Latched
Digital Output 3B Latch Enable Value Output 3B Enable / Disable Latching
Dec 2200 18584 37168
RW
0 Disabled
Hex 0898 4898 9130
1 Enabled
Digital Output 3B Clear Latch Value Output 3B Latch Clear
Dec 2201 18585 37170
RW
0 Do Nothing
Hex 0899 4899 9132
1 Clear Latch
Digital Output 3B Latch State Value Output 3B Latch State
Dec 2202 18586 37172
RO
0 Unlatched
Hex 089A 489A 9134
1 Latched
Output 3 Function Value Output 3 or 3A Function
Dec 10103 26487 52974
RW
0 Disabled
Hex 2777 6777 CEEE
1 Loop 1 Primary Output Power
2 Loop 1 Secondary Output Power
3 Loop 1 VMD Open
4 Loop 1 VMD Close
5 Loop 2 Primary Output Power
6 Loop 2 Secondary Output Power
7 Loop 2 VMD Open
8 Loop 2 VMD Close
9 OR Alarm Event Direct