206
Western Digital Hard Disk Drive OEM Specification
11.25 Read Multiple (C4h)
Command Block Output Registers
Command Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-
Feature
-
-
-
-
-
-
-
-
Error
…See Below
Sector Count
V
V
V
V
V
V
V
V
Sector Count
V
V
V
V
V
V
V
V
Sector Number
V
V
V
V
V
V
V
V
Sector Number
V
V
V
V
V
V
V
V
Cylinder Low
V
V
V
V
V
V
V
V
Cylinder Low
V
V
V
V
V
V
V
V
Cylinder High
V
V
V
V
V
V
V
V
Cylinder High
V
V
V
V
V
V
V
V
Device/Head
1
L
1
D
H
H
H
H
Device/Head
-
-
-
-
H
H
H
H
Command
1
1
0
0
0
1
0
0
Status
…See Below
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY
RDY
DF
DSC
DRQ
COR
IDX
ERR
0
V
0
V
0
V
0
0
0
V
0
V
-
0
-
V
Table 183 Read Multiple Commands (C4h)
The Read Multiple command reads one or more sectors of data from disk media, and then transfers the data from
the device to the host.
The sectors are transferred through the Data Register 16 bits at a time. Command execution is identical to the Read
Sector(s) command except that an interrupt is generated for each block (as defined by the Set Multiple command)
instead of for each sector.