80
Western Digital Hard Disk Drive OEM Specification
9.18.2.1.4 Extended Status Code
Command complete without error
Request sector count overflow. The number of sectors requested to transfer (Sector Count
register) in the read or write log command is larger than required by SCT command.
Invalid Function code in Error Recovery command
Invalid Selection code in Error Recovery command
Host read command timer is less than minimum value
Host write command timer is less than minimum value
Background SCT command was aborted because of an interrupting host command
Background SCT command was terminated because of unrecoverable error
Invalid Function code in Long Sector Access command
SCT data transfer command was issued without first issuing an SCT command
Invalid Function code in Feature Control command
Invalid Feature code in Feature Control command
Invalid New State value in Feature Control command
Invalid Option Flags in Feature Control command
Invalid Table ID (table not supported)
Command was aborted due to drive security being locked
The most recent non-SCT command returned command completion with an error due to
the SCT Error Recovery Control Read Command Timer or SCT Error Recovery Control
Write Command Timer expiring
Blocking SCT Write Same command was terminated because of unrecoverable error
Overlay switch failure in Long Sector Access command
Write Cache enable failure
SCT command executing in background
Table 53 Extended Status Code