EasyManua.ls Logo

Western Digital Ultrastar DC HC310 - Table 226 Set Multiple Commands (C6 H)

Western Digital Ultrastar DC HC310
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
260
Western Digital Hard Disk Drive OEM Specification
11.49 Set Multiple (C6h)
Command Block Output Registers
Command Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-
Feature
-
-
-
-
-
-
-
-
Error
…See Below
Sector Count
V
V
V
V
V
V
V
V
Sector Count
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Device/Head
1
-
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
1
1
0
0
0
1
1
0
Status
…See Below
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY
RDY
DF
DSC
DRQ
COR
IDX
ERR
0
0
0
0
0
V
0
0
0
V
0
-
-
0
-
V
Table 226 Set Multiple Commands (C6h)
The Set Multiple command enables the device to perform Read and Write Multiple commands and establishes the
block size for these commands. The block size is the number of sectors to be transferred for each interrupt.
If an invalid block size is specified, an Abort error will be returned to the host, and Read Multiple and Write Multiple
commands will be disabled.
Output Parameters To The Device
Sector Count.
The block size to be used for Read Multiple and Write Multiple commands. Valid block sizes can be
selected from 0, 1, 2, 4, 8 or 16. If 0 is specified, then Read Multiple and Write Multiple commands
are disabled.

Table of Contents