3.2 Requirement on the Installation Location
Location of installation ...................... Closed room
Air humidity ....................................... 15% - 85%
Height above sea level ...................... max. 1000 m
Horizontal alignment ......................... max. deviation +/-3° (uneven floor)
Floor ................................................. Non-slip surface, dry, no trip hazards
Ambient temperature ......................... +5°C to +40°C
Load-bearing capacity / device.......... Observe weight and dimensions
MODEL DESIGN
[kg]
[mm]
[mm]
[mm]
Tempro basic C 90 Standard 31 235 660 590
Tempro primus C 90
Standard 31 235 660 590
Ensure that all parts of the machine are easily accessible for maintenance
and repair. Keep the workplace clean and uncluttered!
Take into account that the device releases heat and humid air during
operation.
Ensure that there is sufficient ventilation at the location of installation.
If the units are to be installed on platforms, you must provide additional
safety devices (e.g. strips) to prevent the heaters from rolling off (alternatively,
order rollers with locking mechanism available from Wittmann).
The device must not be operated in explosive atmospheres.