EasyManua.ls Logo

Wittmann Tempro basic C 90 - Code-Menu Only for Option Flow Indication; Operatinghour Menu (Code 101)

Default Icon
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tempro basic C 90 & Tempro primus C 90
Page 33
BASIC & PRIMUS C90 V 3.0 english / 10.04.2012
1xMODE
Key Display Function
UP °C
All temperature values at °C
(pressure at bar)
*
(flow at l/min)
*
DOWN °F
All temperature values at °F
(pressure at PSI)
*
(flow at GPM)
*
Only for Option “Flow indication
1xMODE
Taste Display Function
UP P.to
total pressure
(flow)
The selected
pressure is
displayed by
pressing the UP
and DOWN buttons
in menu 5.
DOWN P.Pu
Pump
pressure
1xMODE
1c2 max. flow at Tmax
1xMODE
10.0 value at 1/10 l/min
1xMODE
1P2 pressure at max. flow Tmax
1xMODE
0.0 value at 1/10 bar
1xMODE
1P= max. pressure at Tmax
1xMODE
0.0 value at 1/10 bar
1xMODE
1c1 max. flow at T1
1xMODE
10.0 value at 1 l/min
1xMODE
1P1 pressure at max. flow T1
1xMODE
0.0 value at 1/10 bar
1xMODE
1P- max. pressure at T1
1xMODE
0.0 value at 1/10 bar
1xMODE - - - End
*
only with “Option Flow
7.16 Code-Menu only for Option „Flow indication“:
7.16.1 Operatinghour menu (Code 101)
Key Display Function
5xMODE 123
22xDOWN 101 Code 101
1xMODE Hr Operating hour menu
1xMODE HzE Hundreds- /Ten- /One digit
1xMODE 0 - 999 HZE
1xMODE ztt Tens of thousands- /Thousand digit
1xMODE 0 - 200 ZTT
1xMODE - - - End

Table of Contents