C-5000 COMMUNICATION MANAGEMENT CONTROLLER
INSTALLATION MANUAL
Publication No. 150-041118 Page 5-41
Rev. A Section 5 – Configuration and Programming
Sep 2001
MEMORY TRANSFER
RECEIVING BLOCK=000
The 3-digit hexadecimal number to the right of the display on the lower line will increment from 000 to 1FFF while
the download is in progress. When the download is complete, the C-5000 will automatically restart so it can pick up
the new configuration.
Uploading a Configuration from the C-5000 into RP
The C-5000’s current configuration can be uploaded into the RP software as follows.
• From the HOME page, press the PROG button, and enter the appropriate password.
• Press the MODE button until the following display page appears.
PROG: 2=NEXT 3=BACK
<ENTER>= RP LOAD
• Press the ENTER button to display the following page.
MEMORY TRANSFER
START SENDING
• Ensure the serial cable is connected to both the PC and the C-5000. Ensure the RP software is ready to receive
data. Refer to RP’s user manual for details on how to prepare RP to receive data. Press the LOWER SOFT
button on the C-5000 to initiate the transfer. Once the communication channel is open, the C-5000’s display
will change to the following.
MEMORY TRANSFER
SENDING BLOCK=000
• The 3-digit hexadecimal number to the right of the display on the lower line will increment from 000 to 1FFF
while the upload is in progress. When the upload is complete, the C-5000’s display will return to the following.