Page | 60
2. Remove all four locking clips holding the Flowmeter/Solenoid Module on the bottom end of the Solenoid Flowmeter
Module and remove the 3/8” tube from it. See Figure F2.
3. Disconnect all harness connection and remove the Solenoid Flowmeter Module, Bracket, and Solenoid from the
Rear Enclosure.
4. Remove the Solenoid Flowmeter Module from the bracket by removing the two screws and split washer holding it in
place with a T20 Drive Screwdriver. See Figure F3.
5. Replace the Solenoid Flowmeter Module with a new part and reinstall in the opposite order. Remember to reinstall
the split washer removed when reinstalling the new Solenoid Flowmeter Module to prevent it from getting
damaged.
6. Replace the rest of the fittings/tubing in the reverse order of that it was removed in.