Remote Operation
SCPI Commands for Digital Interfaces
164 Operating Manual for XDC Series Power Supply
Protection Shutdown Sub-Register Commands
Query Protection Shutdown Event
SCPI command:
STATus[<channel>]:OPERation:SHUTdown:PROTection[:EVENt]
?
Query Protection Shutdown Condition
SCPI command:
STATus[<channel>]:OPERation:SHUTdown:PROTection:CONDiti
on?
Enable Protection Shutdown Sub-Register
SCPI command:
STATus[<channel>]:OPERation:SHUTdown:PROTection:ENABle
<status-enable>
Query format:
STATus[<channel>]:OPERation:SHUTdown:PROTection:ENABle?
Set Protection Shutdown Positive Transition Filter
SCPI command:
STATus[<channel>]:OPERation:SHUTdown:PROTection:PTRansi
tion <status-enable>
Query format:
STATus[<channel>]:OPERation:SHUTdown:PROTection:PTRansi
tion?
Set Protection Shutdown Negative Transition Filter
SCPI command:
STATus[<channel>]:OPERation:SHUTdown:PROTection:NTRansi
tion <status-enable>
Query format:
STATus[<channel>]:OPERation:SHUTdown:PROTection:NTRansi
tion?