EasyManuals Logo

Xantrex XDC User Manual

Xantrex XDC
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #149 background imageLoading...
Page #149 background image
Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 147
Protection SHUTdown Sub-Register
Table 4.12 Protection SHUTdown Sub-Register
Remote CONtrol Sub-Register
This identifies which remote interface is controlling the unit. Only one bit is active
at a time with the exception of analog control, where voltage or current alone, or both
may be under remote control. Current share mode is considered to be under local
control, even though the user cannot adjust the voltage setting from the front panel.
Bit Bit Weight Bit Name Description
0 1 Over VOLTage Over voltage protection has tripped
1 2 Under VOLTage Under voltage protection has tripped
2 4 Over CURrent Over current protection has tripped
3 8 Under CURrent Under current protection has tripped
4 16 Over POWer Over power protection has tripped
5 32 Under POWer Under power protection has tripped
6 64 AC Off AC Off protection has tripped
7 128 Over TEMPerature Over temperature protection has tripped
8 256 SENSe Sense protection has tripped
9 512 FOLDback Foldback protection has tripped

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex XDC and is the answer not in the manual?

Xantrex XDC Specifications

General IconGeneral
BrandXantrex
ModelXDC
CategoryPower Supply
LanguageEnglish

Related product manuals