EasyManua.ls Logo

YASKAWA CIPR-GA50CB001

YASKAWA CIPR-GA50CB001
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.4 Fault
266 YASKAWA SIEPC71061753C GA500 Technical Manual
Code Name Causes Possible Solutions
oFA03
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA04
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA05
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA06
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA10
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA11
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA12
Option Card Connection Error
(CN5)
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA13
Option Card Connection Error
(CN5)
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA14
Option Card Connection Error
(CN5)
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.

Table of Contents

Other manuals for YASKAWA CIPR-GA50CB001

Related product manuals