3.6 Control I/O Connections
98 YASKAWA SIEPC71061753C GA500 Technical Manual
3.6 Control I/O Connections
This section gives information about the settings for the listed control circuit I/O signals.
MFDI (terminals S1 to S7)
Pulse train output (terminal MP)
MFAI (terminal A2)
MFAO (terminal AM)
MEMOBUS/Modbus communications (terminals D+, D-, AC)
Set Sinking Mode/Sourcing Mode
Close the circuit between terminals SC-SP and SC-SN to set the sinking mode/sourcing mode and the internal/
external power supply for the MFDI terminals. The default setting for the drive is internal power supply sinking
mode.
NOTICE: Damage to Equipment. Do not close the circuit between terminals SP-SN. If you close the circuits between terminals
SC-SP and terminals SC-SN at the same time, it will cause damage to the drive.
Mode Internal Power Supply (Terminal SN-SP) External 24 V power supply
Sinking Mode
(NPN)
Sourcing Mode
(PNP)
Pulse Train Output
You can use pulse train monitor output terminal MP for sourcing mode or for sinking mode.
Use for sourcing mode
The load impedance changes the voltage level of the pulse train output signal.
Load Impedance
R
L
(kΩ)
Output Voltage
V
MP
(V)
1.5 or more 5 V or more
4.0 or more 8 V or more
10 or more 10 V or more
Note:
Use the formula in Figure 3.46 to calculate the necessary load resistance (kΩ) to increase output voltage V
MP
(V).

Table of Contents

Other manuals for YASKAWA CIPR-GA50CB001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CIPR-GA50CB001 and is the answer not in the manual?

YASKAWA CIPR-GA50CB001 Specifications

General IconGeneral
BrandYASKAWA
ModelCIPR-GA50CB001
CategoryController
LanguageEnglish

Related product manuals