Parameter Details
12
12.10 n: Special Adjustment
YASKAWA SIEPC71061753C GA500 Technical Manual 737
12.10 n: Special Adjustment
n parameters set these functions:
Function to prevent hunting
High-slip braking
Motor line-to-line resistance online tuning
Fine-tune the parameters that adjust motor control
n1: Hunting Prevention
The Hunting Prevention function will not let low inertia or operation with a light load cause hunting. Hunting
frequently occurs when you have a high carrier frequency and an output frequency less than 30 Hz.
n1-01: Hunting Prevention Selection
No.
(Hex.)
Name Description
Default
(Range)
n1-01
(0580)
Hunting Prevention
Selection
Sets the function to prevent hunting.
0
( 0, 1 )
Note:
When you replace a V1000-series drive with a GA500 drive, set n1-01 = 1 [Hunting Prevention Selection = Enabled].
When drive response is more important than the decrease of motor vibration, disable this function.
0 : Disable
1 : Enabled
n1-02: Hunting Prevention Gain Setting
No.
(Hex.)
Name Description
Default
(Range)
n1-02
(0581)
Expert
Hunting Prevention Gain
Setting
Sets the performance of the hunting prevention function. Usually it is not necessary to change this
parameter.
1.00
(0.00 - 2.50)
Adjust this parameter in these conditions:
When n1-01 = 1 [Hunting Prevention Selection = Enabled (Normal)], if oscillation occurs when you operate a
motor with a light load, increase the setting value in 0.1-unit increments.
When n1-01 = 2, if the motor stalls, decrease the setting value in 0.1-unit increments.
n1-03: Hunting Prevention Time Constant
No.
(Hex.)
Name Description
Default
(Range)
n1-03
(0582)
Expert
Hunting Prevention Time
Constant
Sets the primary delay time constant of the hunting prevention function. Usually it is not
necessary to change this parameter.
Determined by o2-04
(0 - 500 ms)
Adjust this parameter in these conditions:
Load inertia is large: Increase the setting value. If the setting value is too high, response will be slower. Also,
there will be oscillation when the frequency is low.
Oscillation occurs at low frequencies: Decrease the setting value.
n1-05: Hunting Prevent Gain in Reverse
No.
(Hex.)
Name Description
Default
(Range)
n1-05
(0530)
Expert
Hunting Prevent Gain in
Reverse
Sets the performance of the hunting prevention function. This parameter adjusts Reverse run.
Usually it is not necessary to change this parameter.
0.00
(0.00 - 2.50)
Note:
When you set n1-05 = 0, the value set in n1-02 [Hunting Prevention Gain Setting] is effective when the motor rotates in reverse.
Adjust this parameter in these conditions:
V/f