3.21 Defaults by Drive Model and Duty Rating ND/HD
302 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
No.
*1
Name Unit Default
- Drive Model - T250 T302 T371 T414
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 01A7 01A8 01A9 01AA
E2-11
(E4-11, E5-
02)
Motor Rated
Power
HP
(kW)
150
(110)
200
(150)
200
(150)
250
(185)
250
(185)
300
(220)
300
(220)
350
(260)
b3-04
V/f Gain
during Speed
Search
% 60 60 60 60 60 60 60 60
b3-06
Speed
Estimation
Current Level
1
- 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
b3-08
Speed
Estimation
ACR P Gain
- 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
b3-26
Direction
Determination
Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy Saving
Filter Time
s 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00
b8-04
Energy Saving
Coefficient
Value
- 36.23 32.79 32.79 30.13 30.13 30.57 30.57 27.13
C5-17
(C5-37)
Motor Inertia kgm
2
1.90 2.10 2.10 3.30 3.30 3.60 3.60 4.10
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 190 223 223 270 270 310 310 370
E2-02
(E4-02)
Motor Rated
Slip
Hz 1.4 1.38 1.38 1.35 1.35 1.3 1.3 1.3
E2-03
(E4-03)
Motor No-
Load Current
A 49 58 58 70 70 81 81 96
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 0.046 0.035 0.035 0.029 0.029 0.025 0.025 0.02
E2-06
(E4-06)
Motor
Leakage
Inductance
% 20 20 20 20 20 20 20 20
E2-10
(E4-10)
Motor Iron
Loss
W 2150 2350 2350 2850 2850 3200 3200 3700
E5-01
PM Motor
Code Selection
- 1248 1248 1249 1249 124A 124A 124A 124A
L2-02
Power Loss
Ride Through
Time
s 2 2 2 2 2 2 2 2
L2-03
Minimum
Baseblock
Time
s 1.7 1.7 1.7 1.8 1.8 1.9 1.9 2
L2-04
Powerloss V/f
Recovery
Ramp Time
s 1 1 1 1 1 1 1.8 1.8
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 380 380 380 380 380 380 380 380
L3-24
Motor Accel
Time @ Rated
Torque
s 0.646 0.673 0.673 0.777 0.777 0.864 0.864 0.91
L8-02
Overheat
Alarm Level
°C 120 120 120 120 125 125 125 125