3.21 Defaults by Drive Model and Duty Rating ND/HD
304 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
No.
*1
Name Unit Default
- Drive Model - T477 T568 T605 T720
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 01AC 01AD 01AE 01AF
E2-11
(E4-11, E5-
02)
Motor Rated
Power
HP
(kW)
350
(260)
400
(300)
400
(300)
450
(335)
450
(335)
500
(370)
500
(370)
600
(450)
E2-02
(E4-02)
Motor Rated
Slip
Hz 1.3 1.25 1.25 1.25 1.25 1 1.25 1
E2-03
(E4-03)
Motor No-
Load Current
A 96 130 130 130 130 130 130 130
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 0.02 0.014 0.014 0.014 0.014 0.012 0.014 0.012
E2-06
(E4-06)
Motor
Leakage
Inductance
% 20 20 20 20 20 20 20 20
E2-10
(E4-10)
Motor Iron
Loss
W 3700 4700 4700 4700 4700 5560 4700 5560
E5-01
PM Motor
Code Selection
- 124A 124A 124A 124A FFFF FFFF FFFF FFFF
L2-02
Power Loss
Ride Through
Time
s 2 2 2 2 2 2 2 2
L2-03
Minimum
Baseblock
Time
s 2 2.1 2.1 2.1 2.1 2.3 2.1 2.3
L2-04
Powerloss V/f
Recovery
Ramp Time
s 1.8 2 2 2 2 2.2 2 2.2
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 380 380 380 380 380 380 380 380
L3-24
Motor Accel
Time @ Rated
Torque
s 0.91 1.392 1.392 1.392 1.392 1.667 1.392 1.667
L8-02
Overheat
Alarm Level
°C 110 110 125 115 133 133 125 125
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2
n1-01
Hunting
Prevention
Selection
- 2 2 2 2 2 2 2 2
n1-03
Hunting
Prevention
Time Constant
ms 100 100 100 100 100 100 100 100
n1-16
Hunting
Prevention
High Fc Gain
- 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
n5-02
Motor Inertia
Acceleration
Time
s 0.91 1.392 1.392 1.392 1.392 1.667 1.392 1.667
*1 Parameters within parentheses are for motor 2.