n
IP20/NEMA Type 1 Enclosure Drives
Note: Removing the top protective cover or bottom conduit bracket from an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection
while maintaining IP20 conformity.
W1
4-d
H1
H
H0
H2
H3
W
Max.W2
D
D1
t2
t1
Figure 2Figure 1
W1
H4
H
H0
H1
H3
H2
D
D1
t1
4-d
W
Max.W2
Table 2.4 Dimensions for IP20/NEMA Type 1 Enclosure: 200 V Class
Drive Model
Dimensions (in)
Figure W H D W1 W2 H0 H1 H2 H3 H4 D1 t1 t2 d Wt. (lb)
2A0004F
1
<1>
5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.3
2A0006F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.3
2A0008F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5
2A0010F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5
2A0012F 5.51 11.81 5.79 4.80 – 10.24 9.76 0.24 1.57 0.06 1.50 0.20 – M5 7.5
2A0018F 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2
2A0021F 5.51 11.81 6.46 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 8.2
2A0030F 5.51 11.81 6.57 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 9.3
2A0040F 5.51 11.81 6.57 4.80 – 10.24 9.76 0.24 1.57 0.06 2.17 0.20 – M5 9.3
2A0056F 7.09 13.39 7.36 6.30 – 11.81 11.18 0.31 1.57 0.06 2.95 0.20 – M5 13.0
2A0069F 8.66 15.75 7.76 7.56 – 13.78 13.19 0.31 1.97 0.06 3.07 0.20 – M6 20.1
2A0081F 8.66 15.75 7.76 7.56 – 13.78 13.19 0.31 1.97 0.06 3.07 0.20 – M6 22.0
2A0110F
2
<1>
10.00 21.02 10.16 7.68 0.31 15.75 15.16 0.30 5.28 – 3.94 0.09 0.09 M6 50.7
2A0138F 10.98 24.17 10.16 8.66 0.31 17.72 17.13 0.30 6.46 – 3.94 0.09 0.09 M6 61.7
2A0169F 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 90.4
2A0211F 12.95 28.74 11.14 10.24 0.31 21.65 21.06 0.30 7.09 – 4.33 0.09 0.09 M6 92.6
Dimensions below are the dimensions of IP00/Open Type models after customer installation of the appropriate IP20/NEMA Type 1 Kit.
2A0250A
2
17.95 37.80 12.99 12.80 0.31 27.76 26.77 0.49 10.04 – 5.12 0.13 0.13 M10 183.0
2A0312A 17.95 37.80 12.99 12.80 0.31 27.76 26.77 0.49 10.04 – 5.12 0.13 0.13 M10 194.0
2A0360A 19.84 45.98 13.78 14.57 0.31 31.50 30.43 0.51 14.49 – 5.12 0.18 0.18 M12 238.1
<1> Removing the top protective cover from a IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while retaining IP20 conformity.
2.1 Mechanical Installation
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
41
2