Table 2.8 Dimensions for IP00/Open Type Enclosure: 200 V Class
Drive
Model
Dimensions (in)
Figure W H D W1 W2 H1 H2 D1 t1 t2 d Wt. (lb)
2A0250A
<1>
1
17.72 27.76 12.99 12.80 0.39 26.77 0.49 5.12 0.13 0.13 M10 167.6
2A0312A
<1>
17.72 27.76 12.99 12.80 0.39 26.77 0.49 5.12 0.13 0.13 M10 176.4
2A0360A
<1>
19.69 31.50 13.78 14.57 0.39 30.43 0.51 5.12 0.18 0.18 M12 216.1
2A0415A 19.69 31.50 13.78 14.57 0.39 30.43 0.51 5.12 0.18 0.18 M12 218.3
<1> Customers may convert these models to IP20/NEMA Type 1 enclosures using an IP20/NEMA Type 1 Kit. Refer to IP20/NEMA Type 1 Kit
Selection on page 47 to select the appropriate kit.
Table 2.9 Dimensions for IP00/Open Type Enclosure: 400 V Class
Drive
Model
Dimensions (in)
Figure W H D W1 W2 W3 W4 H1 H2 D1 t1 t2 d
Wt.
(lb)
4A0208A
<1>
1
17.72 27.76 12.99 12.80 0.39 – – 26.77 0.49 5.12 0.13 0.13 M10 174.2
4A0250A
<1>
19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 211.6
4A0296A
<1>
19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 224.9
4A0362A
<1>
19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 235.9
4A0414A 2 19.69 37.40 14.57 14.57 0.31 – – 36.34 0.51 5.31 0.18 0.18 M12 275.6
4A0515A
3
26.38 44.88 14.57 17.32 0.24 8.66 – 43.70 0.59 5.91 0.18 0.18 M12 476.2
4A0675A 26.38 44.88 14.57 17.32 0.24 8.66 – 43.70 0.59 5.91 0.18 0.18 M12 487.2
<1> Customers may convert these models to IP20/NEMA Type 1 enclosures using an IP20/NEMA Type 1 Kit. Refer to IP20/NEMA Type 1 Kit
Selection on page 47 to select the appropriate kit.
Table 2.10 Dimensions for IP00/Open Type Enclosure: 600 V Class
Drive
Model
Dimensions (in)
Figure W H D W1 W2 W3 W4 H1 H2 D1 t1 t2 d
Wt.
(lb)
5A0125A
<1>
1
17.72 27.76 12.99 12.80 0.39 – – 26.77 0.49 5.12 0.13 0.13 M10 174.2
5A0145A
<1>
17.72 27.76 12.99 12.80 0.39 – – 26.77 0.49 5.12 0.13 0.13 M10 174.2
5A0192A
<1>
19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 235.9
5A0242A
<1>
19.69 31.50 13.78 14.57 0.39 – – 30.43 0.51 5.12 0.18 0.18 M12 235.9
<1> Customers may convert these models to IP20/NEMA Type 1 enclosures using an IP20/NEMA Type 1 Kit. Refer to IP20/NEMA Type 1 Kit
Selection on page 47 to select the appropriate kit.
2.1 Mechanical Installation
46