10 Appendix
10.1.1 List of Parameters
10-6
Pn007 Function Selection Application Switch 7
−−0000 Immedi-
ately
8.2
Pn008 Function Selection Application Switch 8
−−0000 After
restart
Pn100 Speed Loop Gain
1.0 to 2000.0 Hz 0.1 Hz 40.0 Hz After
restart
Parameter
No.
Name Setting Range Units
Factory
Setting
Setting
Validation
Reference
Section
Analog Monitor 2 Signal Selection
00
Motor speed (1 V/1000 min
-1
)
01
Reserved
02
Torque reference (1 V/100%) - Gravity compensation (Pn422)*
03
Reserved
04
Reserved
05
Reserved
06
Reserved
08
Reserved
0B
Reserved
0C
Reserved
0D
Reserved
0E
Reserved
0F
Reserved
Analog Monitor 2 Signal Multiplication Selection
0
× 1
1
× 10
2
× 100
3
× 1/10
4
× 1/100
Reserved (Do not change)
3rd 2nd 1st 0
digit digit digit digit
n. FFFF
Analog monitor 2 output voltage
= [(-1) ー Signal selection (Pn007.0) ー Signal multiplication (Pn007.2) ] + Offset voltage (Pn551)
* The torque reference outputs a value "Torque reference value output from SERVOPACK - Gravity compensation (Pn422)"
for monitor.
Lowered Battery Voltage Alarm/Warning Selection
0
Outputs alarm (A.830) for lowered battery voltage.
1
Outputs warning (A.930) for lowered battery voltage.
Reserved (Do not change)
Warning Detection Selection
0
Detects warning.
1
Does not detect warning.
Reserved (Do not change)
3rd 2nd 1st 0
digit digit digit digit
n. FFFF
SIEPS80000025.book 6 ージ 20  