8.2 Analog Monitor
8-5
8
8.2 Analog Monitor
Signals for analog voltage references can be monitored.
To monitor analog signals, connect the analog monitor cable (JZSP-CA01) to the connector CN5.
The analog monitor signals can be changed by setting parameters Pn006.0,1 and Pn007.0,1.
The output voltages on analog monitor 1 and 2 are set as shown below.
Line Color Signal Name Description
White
Analog monitor 1 Torque reference: 1 V/100% Rated torque
Red
Analog monitor 2
Motor speed: 1 V/1000 min
-1
Black (2 lines)
GND (0 V) Analog monitor GND: 0 V
CN5
White
Red
Black
Black
Analog monitor 1 output voltage = {(-1) × Signal selection × Signal multiplier } + Offset voltage [V]
Pn006= XX
Pn006=
X
Pn550
Analog monitor 2 output voltage = {(-1) × Signal selection × Signal multiplier } + Offset voltage [V]
Pn007= XX
Pn007=
X
Pn551
SIEPS80000025.book 5 ージ 20  