Digital Operation Display Functions and Levels
5-9
* 1. The factory setting depends on the Inverter capacity.
* 2. These are values for a 200 V class Inverter. Values for a 400 V class Inverter are double.
* 3. After autotuning, E1-13 will contain the same value as E1-05.
* 4. The factory setting depends on the Inverter capacity. (The value for a 200 V Class Inverter for 0.4 kW is given.)
* 5. The setting range is from 10% to 200% of the Inverter rated output current. (The value for a 200 V Class Inverter for 0.4 kW is given.)
* 6. Parameter is only effective if HOA operator with LCD (JVOP-162) is used.
o1-05 LCD-Focus
Sets the brightness on the optional LCD
operator (JVOP-160).
0: light
1:
2:
3: normal
4:
5: dark
0 to 5 3 Yes A 509H
o1-07
2nd Monitor
Selection
*6
Selects the monitor that is displayed and
locked in the second line of the operator
display
1 to 53 2 No A 518H
o1-08
3rd Monitor
Selection
*6
Selects the monitor that is displayed and
locked in the third line of the operator dis-
play
1 to 53 3 No A 519H
o2-03
User constant
initial value
Clears or stores user initial values.
0: Stores/not set
1: Begins storing (Records the set
constants as user initial values.)
2: All clear (Clears all recorded user
initial values)
When the set constants are recorded as
user initial values, 1110 will be set in
A1-03.
0 to 2 0 No A 507H
o2-05
Frequency refer-
ence setting
method selection
When the frequency reference is set on
the Digital Operator frequency reference
monitor, sets whether the Enter key is
necessary or not.
0: Enter key needed
1: Enter key not needed
When set to 1, the Inverter accepts the fre-
quency reference without Enter key oper-
ation.
0 or 1 0 No A 509H
o2-08
Cumulative
operation time
selection
0: Cumulative time when the Inverter
power is on. (All time while the
Inverter power is on is accumulated.)
1: Cumulative Inverter run time. (Only
Inverter output time is accumulated.)
0 or 1 0 No A 50CH
o3-02
Read permis-
sion selection
0: READ prohibited
1: READ permitted
0 or 1 0 No A 516H
Con-
stant
Number
Name Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Access
Level
MEMO-
BUS
Regis-
ter
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for YASKAWA Varispeed E7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed E7 and is the answer not in the manual?

YASKAWA Varispeed E7 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed E7
CategoryDC Drives
LanguageEnglish

Related product manuals