4
-30
Open-loop
vector 1
control
(A1-02 = 2)
Carrier frequency
selection (C6-02)
Reducing motor
magnetic noise
Controlling hunting
and vibration at low
speeds (10 Hz or
less)
Depends
on capac-
ity
0 to
default
Increase the setting if
motor magnetic noise is
high.
Reduce the setting if hunt-
ing or vibration occurs at
low speeds.
Middle output
frequency voltage
(E1-08)
Minimum output
frequency voltage
(E1-10)
Improving torque at
low speeds
Controlling shock at
startup
Depends
on capac-
ity and
voltage
Default to
Default + 1
or 2 V
*
Increase the setting if
torque or speed response is
slow.
Reduce the setting if shock
at startup is large.
Flux vector
control
(A1-02 = 3)
ASR proportional gain
1 (C5-01) and
ASR proportional gain
2 (C5-03)
Torque and speed
response
Controlling hunting
and vibration
20.00
10.00 to
50.00
Increase the setting if
torque or speed response is
slow.
Reduce the setting if hunt-
ing or vibration occurs.
ASR integral time 1
(high-speed) (C5-02)
and
ASR integral time 2
(low-speed) (C5-04)
Torque and speed
response
Controlling hunting
and vibration
0.500 s
0.300 to
1.000 s
Reduce the setting if
torque or speed response is
slow.
Increase the setting if hunt-
ing or vibration occurs.
ASR switching
frequency (C5-07)
Switching the ASR
proportional gain and
integral time accord-
ing to the output fre-
quency
0.0 Hz
0.0 to max.
output fre-
quency
Set the output frequency at
which to change the ASR
proportional gain and inte-
gral time when the same val-
ues cannot be used for both
high-speed and low-speed
operation.
ASR primary delay
time (C5-06)
Controlling hunting
and vibration
0.004 s
0.004 to
0.020 s
Increase the setting if
machine rigidity is low and
the system vibrates easily.
Carrier frequency
selection (C6-02)
Reducing motor
magnetic noise
Controlling hunting
and vibration at low
speeds (3 Hz or less)
Depends
on the
capacity.
2.0 kHz to
default
Increase the setting if
motor magnetic noise is
high.
Reduce the setting if hunt-
ing or vibration occurs at
low speeds.
Open-loop
vector 2
control
(A1-02 = 4)
ASR proportional gain
(C5-01, C5-03)
Torque and speed
response
Controlling hunting
and vibration
10.00
10.00 to
50.00
Increase the setting if
torque or speed response is
slow.
*2
Reduce the setting if hunt-
ing or vibration occurs.
ASR integral times
(C5-02, C5-04)
Torque and speed
response
Controlling hunting
and vibration
0.500 s
0.300 to
1.000 s
Reduce the setting if
torque or speed response is
slow.
Increase the setting if hunt-
ing or vibration occurs.
Table 4.3 Adjusted User Constants (Continued)
Control
Method
Name (Constant
Number)
Performance
Factory
Setting
Recom-
mended
Setting
Adjustment Method
TOE-S616-60.1.book 30 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals