EasyManuals Logo

YASKAWA Varispeed G7 Series User Manual

YASKAWA Varispeed G7 Series
541 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
5
-22
C: Autotuning Constants
The following settings are made with the autotuning constants (C constants): Acceleration/deceleration times,
s-curve characteristics, slip compensation, torque compensation, speed control, and carrier frequency func-
tions.
Acceleration/Deceleration: C1
User constants for acceleration and deceleration times are shown in the following table.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
C1-01
Accelera-
tion time 1
Sets the acceleration time to
accelerate from 0 to the maxi-
mum output frequency, in 1-
second units.
0.0 to
6000.0
*
10.0 s
YesQQQQQ200H
4-7
4-33
6-18
Accel Time
1
C1-02
Decelera-
tion time 1
Sets the deceleration time to
decelerate from the maximum
output frequency to 0, in 1-
second units.
YesQQQQQ201H
4-7
4-33
6-18
Decel Time
1
C1-03
Accelera-
tion time 2
The acceleration time when
the multi-function input
“accel/decel time 1” is set to
ON.
YesAAAAA202H
4-33
6-18
Accel Time
2
C1-04
Decelera-
tion time 2
The deceleration time when
the multi-function input
“accel/decel time 1” is set to
ON.
YesAAAAA203H
4-33
6-18
Decel Time
2
C1-05
Accelera-
tion time 3
The acceleration time when
the multi-function input
“accel/decel time 2” is set to
ON.
NoAAAAA204H
4-33
6-18
Accel Time
3
C1-06
Decelera-
tion time 3
The deceleration time when
the multi-function input
“accel/decel time 2” is set to
ON.
NoAAAAA205H
4-33
6-18
Decel Time
3
C1-07
Accelera-
tion time 4
The acceleration time when
the multi-function input
“accel/decel time 1” and
“accel/decel time 2” are set to
ON.
NoAAAAA206H
4-33
6-18
Accel Time
4
C1-08
Decelera-
tion time 4
The deceleration time when
the multi-function input
“accel/decel time 1” and
“accel/decel time 2” are set to
ON.
NoAAAAA207H
4-33
6-18
Decel Time
4
C1-09
Emergency
stop time
The deceleration time when
the multi-function input
“Emergency (fast) stop” is set
to ON.
This function can be used as a
stopping method when a fault
has been detected.
NoAAAAA208H
4-33
6-17
Fast Stop
Time
TOE-S616-60.1.book 22 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals