Conformance to CE Markings
10-
13
10
Conformance to CE Markings
Points regarding conformance to CE markings are given below.
CE Markings
CE markings indicate conformance to safety and environmental standards that apply to business transactions
(including production, imports, and sales) in Europe. There are unified European standards for mechanical
products (Machine Directive), electrical products (Low Voltage Directive), and electrical noise (EMC Direc-
tive). CE markings are required for business transactions in Europe (including production, imports, and sales).
The Varispeed G7-Series Inverters bear CE markings indicating conformance to the Low Voltage Directive
and the EMC Directive.
Low Voltage Directive: 2006/95/EC
EMC Directive: 2004/108/EC
Machinery and installations that incorporate the Inverter are also subject to CE markings. It is ultimately the
responsibility of customers making products incorporating the Inverter to attach CE markings to the finished
products. The customer must confirm that the finished products (machines or installations) conform to the
European Standards.
Requirements for Conformance to CE Markings
Low Voltage Directive
Varispeed G7-Series Inverters satisfy testing for conformance to the Low Voltage Directive under the condi-
tions described in European Standard EN50178.
Requirements for Conformance to the Low Voltage Directive
Varispeed G7-Series Inverters must satisfy the following conditions in order to conform to the Low Voltage
Directive.
It must be used under conditions corresponding to overvoltage category 3 or less and pollution degree 2 or
less as specified in IEC664.
Input fuses:
For details on selecting fuses, refer to Table 10.4 Selection Requirements for Input Fuses with Examples.
With Inverters CIMR-G7A2018 to 2110 and CIMR-G7A4018 to 4300, an enclosure preventing foreign
matter from entering from the top or front sides is required (IP4X or higher: panel installation).
TOE-S616-60.1.book 13 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals