User Constant Tables
5-
55
Multi-function Analog Outputs: H4
User constants for multi-function analog outputs are shown in the following table.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
H4-01
Monitor
selection
(terminal
FM)
Sets the number of the monitor
item to be output (U1-)
from terminal FM.
4, 10 to 14, 25, 28, 34, 39, 40
cannot be set. 29 to 31 and 41
are not used.
1 to 45
2 NoAAAAA41DH6-89
Terminal
FM Sel
1 to 99
H4-02
Gain (ter-
minal FM)
Sets the multi-function analog
output 1 voltage level gain.
Sets whether the monitor item
output will be output in multi-
ples of 10 V.
The maximum output from the
terminal is 10 V. A meter cali-
bration function is available.
*
0.00 to
2.50
1.00 Yes Q Q Q Q Q 41EH
4-8
6-89
Terminal
FM Gain
H4-03
Bias (termi-
nal FM)
Sets the multi-function analog
output 1 voltage level bias.
Sets output characteristic up/
down parallel movement as a
percentage of 10 V.
The maximum output from the
terminal is 10 V. A meter cali-
bration function is available.
*
-10.0 to
+10.0
0.0% Yes A A A A A 41FH 6-89
Terminal
FM Bias
H4-04
Monitor
selection
(terminal
AM)
Sets the number of the monitor
item to be output (U1-)
from terminal AM.
4, 10 to 14, 25, 28, 34, 39, 40
cannot be set. 29 to 31 and 41
are not used.
1 to 45
3 No A A A A A 420H 6-89
Terminal
AM Sel
1 to 99
H4-05
Gain (ter-
minal AM)
Set the voltage level gain for
multi-function analog output 2.
Set the number of multiples of
10 V to be output as the 100%
output for the monitor items.
The maximum output from the
terminal is 10 V. A meter cali-
bration function is available.
*
0.00 to
2.50
0.50 Yes Q Q Q Q Q 421H
4-8
6-89
Terminal
AM Gain
H4-06
Bias (termi-
nal AM)
Sets the multi-function analog
output 2 voltage level bias.
Sets output characteristic up/
down parallel movement as a
percentage of 10 V.
The maximum output from the
terminal is 10 V. A meter cali-
bration function is available.
*
-10.0 to
+10.0
0.0% Yes A A A A A 422H 6-89
Terminal
AM Bias
H4-07
Analog out-
put 1 signal
level selec-
tion
Sets the signal output level for
multi-function output 1 (termi-
nal FM)
0: -10 to 10 V output
1: -10 to 10 V output
0 or 1 0 No A A A A A 423H 6-90
AO Level
Select1
TOE-S616-60.1.book 55 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals