User Constant Tables
5-
89
Fault History: U3
User constants for the error log are shown in the following table.
Note The following errors are not recorded in the error log: CPF00, 01, 02, 03, UV1, and UV2.
Con-
stant
Number
Name
Description
Output Signal Level
During Multi-Function
Analog Output
Min.
Unit
Control Methods
MEMO-
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
-loop
Vec-
tor
2
U3-01
Most recent
fault
The error contents of 1st
previous fault.
(Cannot be output.)
–AAAAA90H
Last Fault
U3-02
Second most
recent fault
The error contents of 2nd
previous fault.
–AAAAA91H
Fault
Message 2
U3-03
Third most
recent fault
The error contents of 3rd
previous fault.
–AAAAA92H
Fault
Message 3
U3-04
Fourth/oldest
fault
The error contents of 4th
previous fault.
–AAAAA93H
Fault
Message 4
U3-05
Cumulative
operation
time at fault
The total operating time
when the 1st previous fault
occurred.
1
hr
AAAAA94H
Elapsed Time
1
U3-06
Accumulated
time of
second fault
The total operating time
when the 2nd previous fault
occurred.
1
hr
AAAAA95H
Elapsed Time
2
U3-07
Accumulated
time of third
fault
The total operating time
when the 3rd previous fault
occurred.
1
hr
AAAAA96H
Elapsed Time
3
U3-08
Accumulated
time of
fourth/oldest
fault
The total operating time
when the 4th previous fault
occurred.
1
hr
AAAAA97H
Elapsed Time
4
TOE-S616-60.1.book 89 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals