Acceleration and Deceleration Characteristics
6-
19
* The setting range for acceleration/deceleration times depends on the setting of C1-10 (Acceleration/deceleration Time Setting Unit). If C1-10 is set to 0,
the setting range is 0.00 to 600.00 (s).
Setting Acceleration and Deceleration Time Units
Set the acceleration/deceleration time units using C1-10. Constant C1-10 is set to 1 at the factory.
Switching Acceleration and Deceleration Time Using Multi-Function Input Terminal
Commands
Using the Inverter, you can set four acceleration times and four deceleration times. When the multi-function
input terminals (H1-) are set to 7 (acceleration/deceleration time selection 1) and 1A (acceleration/decel-
eration time selection 2), you can switch the acceleration/deceleration time even during operation by combin-
ing the ON/OFF status of the terminals.
The following table shows the acceleration/deceleration time switching combinations.
C1-11
Accel/decel
time switch-
ing frequency
Sets the frequency for automatic
acceleration/deceleration switching.
Below set frequency: Accel/decel
time 4
Above set frequency: Accel/decel
time 1
The multi-function input “accel/
decel time 1” or “accel/decel time
2” take priority.
0.0 to
400.0
0.0 Hz No A A A A A 20AH
Acc/Dec SW
Freq
C2-01
S-curve char-
acteristic time
at accelera-
tion start
All sections of the S-curve charac-
teristic time are set in seconds units.
When the S-curve characteristic
time is set, the accel/decel times
will increase by only half of the S-
curve characteristic times at start
and end.
0.00 to
2.50
0.20 s No A A A A A 20BH
SCrv Acc @
Start
C2-02
S-curve char-
acteristic time
at accelera-
tion end
0.00 to
2.50
0.20 s No A A A A A 20CH
SCrv Acc @
End
C2-03
S-curve char-
acteristic time
at decelera-
tion start
0.00 to
2.50
0.20 s No A A A A A 20DH
SCrv Dec @
Start
C2-04
S-curve char-
acteristic time
at decelera-
tion end
0.00 to
2.50
0.00 s No A A A A A 20EH
SCrv Dec @
End
Set value Details
0 The acceleration/deceleration time settings range is 0.00 to 600.00 in units of 0.01 s.
1 The acceleration/deceleration time settings range is 0.00 to 6000.0 in units of 0.1 s.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
Run Command
Output
frequency
Time
ON
OFF
C2-02 C2-03
C2-04
C2-01
TOE-S616-60.1.book 19 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals