Individual Functions
6-
139
* 1. When the control method is changed, the factory settings will change. The flux vector factory settings are given.
* 2. The setting range for flux vector and open-loop vector 2 controls is 1.00 to 300.00.
Multi-function Contact Input Functions (H1-01 to H1-10)
C5-03
ASR propor-
tional (P)
gain 2
Usually setting is not necessary.
Set to change the rotational speed gain.
0.00 to
300.00
*2
20.00
*1
Yes N o A N o A A
21DH
ASR P Gain
2
C5-04
ASR inte-
gral (I) time
2
0.000
to
10.000
0.500
s
*1
Yes N o A N o A A
21EH
ASR I Time
2
C5-05
ASR limit Sets the upper limit for the compensation
frequency for the speed control loop
(ASR) to a percentage of the maximum
output frequency.
0.0 to
20.0
5.0% No No A No No No 21FH
ASR Limit
C5-06
ASR pri-
mary delay
time
Sets the filter time constant for outputting
torque references from the speed control
loop (ASR). It is set in 1-second units.
With open-loop vector 2 control, this set-
ting is enabled only for speeds in the
range 0 to 35 Hz.
Usually setting is not necessary.
0.000
to
0.500
0.004s
*1
No No No No A A 220H
ASR Delay
Time
C5-07
ASR switch-
ing fre-
quency
Set the frequency for switching between
Proportion Gain 1, 2 and Integral Time 1,
2 in Hz units.
Speed control (ASR) proportional gain
switching for a multi-function input takes
priority.
0.0 to
400.0
0.0 Hz No No No No A A 221H
ASR Gain
SW Freq
C5-08
ASR inte-
gral (I) limit
Set the upper limit of the speed control
loop integral as a percentage of the value
at the rated load.
0 to
400
400% No No No No A A 222H
ASR I Limit
C5-10
ASR pri-
mary delay
time 2
Sets the filter time constant for outputting
torque references from the speed control
loop (ASR). It is set in 1-second units.
With open-loop vector 2 control, this set-
ting is enabled only for speeds greater
than 35 Hz.
Usually setting is not necessary.
0.000
to
0.500
0.010
s
No No No No No A 231H
ASR Delay
Time2
Set-
ting
Value
Function
Control Methods
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
D
Speed control disable setting for V/f control with PG
OFF: Use speed control V/f control with PG
ON: Do not use speed control for V/f control with PG
NoYesNoNoNo
E
Speed control integral reset
Enables switching between PI and P control for the speed control loop.
No No No Yes Yes
77
Speed control (ASR) proportional gain switch (switching between C5-01 and C5-03)
OFF: Use proportional gain in C5-01
ON: Use proportional gain in C5-03
No No No Yes Yes
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Reg-
ister
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
P, I
0 E1-04 Motor speed (Hz)
P=C5-01
I=C5-02
P=C5-03
I=C5-04
TOE-S616-60.1.book 139 ページ 017年8月4日 金曜日 午後3時41分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals