Digital Operator Functions
6-
155
Select READ Permitted
Prevent overwriting the data stored in EEPROM in the Digital Operator by mistake. With o3-02 set to 0, if you
set o3-01 to 1, and perform the write operation, PrE will be displayed on the Digital Operator, and the write
operation will be stopped.
Writing Constant Set Values Stored in the Digital Operator to the Inverter (COPY)
To write constant set values stored in the Digital Operator to the Inverter, make the settings using the follow-
ing method.
Read data length mismatch or read data error.
Tried to write constants to EEPROM on the Digital Operator, but unable to perform write
operation.
Table 6.2 COPY Function Procedure
Step
No.
Digital Operator Display Explanation
1 Press the MENU Key, and select advanced programming mode.
2 Press the DATA/ENTER Key, and select the constants monitor display.
3
Display o3-01 (Copy Function Selection) using the Increment Key and Decrement
Key.
4 Press the DATA/ENTER Key, and select the constants setting display.
5 Change the set value to 2 using the Increment Key.
6 Set the changed data using the DATA/ENTER Key. The COPY function will start.
7 If the COPY function ends normally, End is displayed on the Digital Operator.
Error Display Meaning
** Main Menu **
-ADV-
Programming
Initialization
-ADV-
A1 - 00=1
Select Language
COPY Function
-ADV-
o3 - 01=0
Copy Funtion Sel
Copy Funtion Sel
-ADV-
o3-01= 0
COPY SELECT
*0*
Copy Funtion Sel
-ADV-
o3-01= 2
OP→INV WRITE
*0*
TOE-S616-60.1.book 155 ページ 2017年8月4日 金曜日 午後3時41分