EasyManua.ls Logo

YASKAWA Varispeed G7 Series

YASKAWA Varispeed G7 Series
541 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protective and Diagnostic Functions
7-
11
CPF03
EEPROM
Error
EEPROM Error
Try turning the power supply off
and on again.
The Inverter power supply was shut off
while writing data to the Inverter con-
stants.
Initialize the constant settings (A1-
03).
The control circuit is damaged. Replace the Inverter.
CPF04
Internal
A/D Err
CPU Internal A/D Converter
Error
Try turning the power supply off
and on again.
The control circuit is damaged. Replace the Inverter.
A short-circuit between +V, V, and
AC terminals occurred.
Overload in the control circuit termi-
nal.
Make sure that incorrect wiring
has not been done.
Check the resistance and wiring
for the frequency setting potenti-
ometer, etc. (Check that the cur-
rent for terminals +V and –V is
20 mA or less.)
CPF05
External
A/D Err
CPU External A/D Converter
Error
Try turning the power supply off
and on again.
The control circuit is damaged. Replace the Inverter.
A short-circuit between +V, V, and
AC terminals occurred.
Overload in the control circuit termi-
nal.
Make sure that incorrect wiring
has not been done.
Check the resistance and wiring
for the frequency setting potenti-
ometer, etc. (Check that the cur-
rent for terminals +V and –V is
20 mA or less.)
CPF06
Option
error
Option Board Connection Error
The option board is not connected prop-
erly.
Turn off the power and insert the
board again.
The Inverter or option board is faulty.
Replace the option board or the
Inverter.
CPF07
RAM-Err
ASIC Internal RAM Fault
Try turning the power supply off
and on again.
The control circuit is damaged. Replace the Inverter.
CPF08
WAT- Er r
Watchdog Timer Fault
Try turning the power supply off
and on again.
The control circuit is damaged. Replace the Inverter.
CPF09
CPU-Err
CPU-ASIC Mutual Diagnosis
Fault
Try turning the power supply off
and on again.
The control circuit is damaged. Replace the Inverter.
CPF10
ASIC-Err
ASIC Version Fault The Inverter control circuit is faulty Replace the Inverter.
CPF20
Option
A/D error
Communications Option Board
A/D Converter Error
The option board is not connected prop-
erly.
Turn off the power and insert the
board again.
The option board's A/D
converter is
faulty
.
Replace the Communications
Option Board.
Table 7.1 Fault Displays and Processing (Continued)
Display Meaning Probable Causes Corrective Actions
TOE-S616-60.1.book 11 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Related product manuals