7
-14
Table 7.2 Causes and Corrective Actions When the Digital Operator Goes Dark
Display Meaning Probable Causes Corrective Actions
No display
There was a drop in control power
voltage.
A short-circuit between +V, V, and
AC terminals occurred.
Overload in the control circuit ter-
minal.
Make sure that incorrect wiring
has not been done.
Check the resistance and wir-
ing for the frequency setting
potentiometer, etc. (Check that
the current for terminals +V and
–V is 20 mA or less.)
The short-circuit bar between +1 and
+2 terminals in the main circuit has
been removed.
Attach the short-circuit bar.
P terminal and N terminal of the Brak-
ing Unit are connected in reverse.
Check the wiring for the Brak-
ing Unit, including cables con-
nected to the Braking Unit and
relay terminals.
Replace the Inverter.
Control power circuit failure
Charge indicator is lit:
Replace the Digital Operator.
Replace the board or the
Inverter.
Charge indicator is not lit:
Check the input power supply
voltage.
Replace the Inverter.
Malfunction occurred in the control
power circuit.
Turn OFF the power, wait for 5
minutes, and turn ON the power
again.
The Digital Operator is not connected
properly.
Turn OFF the power, disconnect
the Digital Operator, and then
reconnect it again.
TOE-S616-60.1.book 14 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals