9
-8
* 1. Under development.
* 2. Applicable for G7-Series Inverters with software versions PRG S1038 and later.
Built-in
(con-
nected
to con-
nector)
Com-
muni-
cations
Option
Boards
DeviceNet
Communica-
tions Inter-
face Board
SI-N
73600-
C021X
Used to communicate with an Inverter from a host computer
using DeviceNet communications to start/stop Inverter opera-
tion, read/set user constants, and read/set monitor constants
(output frequencies, output currents, etc.).
ProfiBus-DP
Communica-
tions Inter-
face Board
SI-P
73600-
C022X
Used to communicate with an Inverter from a host computer
using ProfiBus-DP communications to start/stop Inverter
operation, read/set user constants, and read/set monitor con-
stants (output frequencies, output currents, etc.).
ProfiBus-DP
Communica-
tions Inter-
face Board
SI-P1
73600-
C033X
InterBus-S
Communica-
tions Inter-
face Board
SI-R
*1
Used to communicate with an Inverter from a host computer
using InterBus-S communications to start/stop Inverter opera-
tion, read/set user constants, and read/set monitor constants
(output frequencies, output currents, etc.).
CANopen
Communica-
tions Inter-
face Board
SI-S1
*1
Used to communicate with an Inverter from a host computer
using CANopen communications to start/stop Inverter opera-
tion, read/set user constants, and read/set monitor constants
(output frequencies, output currents, etc.).
ControlNet
Communica-
tions Inter-
face Board
SI-U
*1
Used to communicate with an Inverter from a host computer
using ControlNet communications to start/stop Inverter opera-
tion, read/set user constants, and read/set monitor constants
(output frequencies, output currents, etc.).
CC-Link
Communica-
tions Inter-
face Board
SI-C
73600-
C032X
Used to communicate with an Inverter from a host computer
using CC-Link communications to start/stop Inverter opera-
tion, read/set user constants, and read/set monitor constants
(output frequencies, output currents, etc.).
L
ONWORKS
Communica-
tions Inter-
face Board
SI-J
73600-
C035X
Used to communicate with an Inverter from a host computer
using L
ONWORKS communications to start/stop Inverter
operation, read/set user constants, and read/set monitor con-
stants (output frequencies, output currents, etc.).
L
ONWORKS
Communica-
tions Inter-
face Board
SI-W1
73600-
C034X
Used to communicate with an Inverter from a host computer
using L
ONWORKS communications to start/stop Inverter
operation, read/set user constants, and read/set monitor con-
stants (output frequencies, output currents, etc.).
With Display Data Channel (DDC) function.
MECHA-
TROLINK-
Communi-
cations Inter-
face Board
SI-T
*2
100-017-994
Used to communicate with an Inverter from a host computer
using MECHATROLINK communications to start/stop
Inverter operation, read/set user constants, and read/set moni-
tor constants (output frequencies, output currents, etc.).
Table 9.4 Option Boards (Continued)
Type Name
Code Num-
ber
Function
Document
Number
TOE-S616-60.1.book 8 ージ 2017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals