238
Note: When using a 5.5-kW or 7.5-kW Inverter (200 V or 400 V Class), the
Inverter can be used as an IP00 device if the top and bottom covers are
removed.
400 V
3-
phase
0.37 108
(4.25)
128
(5.04)
107
(4.21)
96
(3.78)
118
(4.65)
5
(0.20)
M4 1.0
(2.20)
9.4 13.7 23.1 2
0.55 108
(4.25)
128
(5.04)
125
(4.92)
96
(3.78)
118
(4.65)
5
(0.20)
M4 1.1
(2.43)
15.1 15.0 30.1 2
1.1 108
(4.25)
128
(5.04)
155
(6.10)
96
(3.78)
118
(4.65)
5
(0.20)
M4 1.5
(3.31)
30.3 24.6 54.9 2
1.5 108
(4.25)
128
(5.04)
171
(6.73)
96
(3.78)
118
(4.65)
5
(0.20)
M4 1.5
(3.31)
45.8 29.9 75.7 2
2.2 108
(4.25)
128
(5.04)
171
(6.73)
96
(3.78)
118
(4.65)
5
(0.20)
M4 1.5
(3.31)
50.5 32.5 83.0 2
3.0 140
(5.51)
128
(5.04)
158
(6.22)
128
(5.04)
118
(4.65)
5
(0.20)
M4 2.1
(4.62)
58.2 37.6 95.8 2
3.7 140
(5.51)
128
(5.04)
158
(6.22)
128
(5.04)
118
(4.65)
5
(0.20)
M4 2.1
(4.62)
73.4 44.5 117.9 2
5.5 180
(7.08)
260
(10.23)
185
(7.28)
164
(6.46)
244
(9.60)
8
(0.31)
M5 4.8
(10.58)
168.8 87.7 256.5 2
7.5 180
(7.08)
260
(10.23)
185
(7.28)
164
(6.46)
244
(9.60)
8
(0.31)
M5 4.8
(10.58)
209.6 99.3 308.9 2
Volt -
age
class
Ca-
paci-
ty
(kW)
W H D W1 H1 H2 d Mass Heat Loss (W) Fig.
Heat-
sink
Unit Total