10. Specifications
227
Standard Specifications (400 V Class)
Voltage Class 400 V 3-phase
Model
CIMR-
V7
*1
C

3-
phase
40P2 40P4 40P7 41P5 42P2 43P0 43P7 45P5 47P5
Single-
phase
---------
Max. Applicable
Motor Output kW
*1
0.37 0.55 1.1 1.5 2.2 3.0 3.7 5.5 7.5
Inverter
Capacity
(kVA)
0.9 1.4 2.6 3.7 4.2 5.5 7.0 11 14
Rated Out-
put Current
(A)
1.2 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18
Max. Output
Voltage (V)
3-phase, 380 to 460 V (proportional to input voltage)
Max. Output
Frequency
(Hz)
400 Hz (Programmable)
Rated Input
Voltage and
Frequency
3-phase, 380 to 460 V, 50/60 Hz
Allowable
Voltage Fluc-
tuation
15 to +10%
Allowable
Frequency
Fluctuation
±5%