EasyManuals Logo

Yeastar Technology MyPBX U100 User Manual

Yeastar Technology MyPBX U100
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
MyPBX U100&U200 Administrator's Guide
www.yeastar.com Page 60
·PRI Dial Plan
Sets an option required for some (rare) switches that require a dial plan
parameter to be passed. This option is ignored by most BRI switches. It may be
necessary on a few pieces of hardware. This option can almost always be left
unchanged from the default.
·Reset interval
Sets the time in seconds between restart of unused channels. Some PBXs don't
like channel restarts. so set the interval to a very long interval e.g. 100000000
or 'never' to disable *entirely*. If you are in Israel, the following is important:
As Bezeq in Israel doesn't like the B-Channel resets happening on the lines, it is
best to set the reset interval to 'never' when installing a box in Israel. Our past
experience also shows that this parameter may also cause issues on local
switches in the UK and China.
·PRI Local Dial Plan
Sets an option required for some (rare) switches that require a dial plan
parameter to be passed. This option is ignored by most BRI switches. It may be
necessary on a few pieces of hardware. This option can almost always be left
unchanged from the default.
·Over Lap Dial
Whether MyPBX can dial this switch using overlap digits. If you need Direct
Dial-in (DDI; in German "Durchwahl") you should change this to yes, then
MyPBX will wait after the last digit it receives.
·PRI Indication
Tells how Device should indicate Busy() and Congestion() to the switch/user.
Accepted values are:
inband: Device plays indication tones without answering; not available on all
PRI/BRI subscription lines .
outofband: Device disconnects with busy/congestion information code so the
switch will play the indication tones to the caller. Busy() will now do same as
setting PRI_CAUSE=17 and Hangup().
·Enable Facility
To enable transmission of facility-based ISDN supplementary services (such as
caller name from CPE over facility) .
·NSF
Used with AT&T PRIs. If outbound calls are being rejected due to "Mandatory
information element missing" and the missing IE is 0x20, then you need this
setting.

Table of Contents

Other manuals for Yeastar Technology MyPBX U100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yeastar Technology MyPBX U100 and is the answer not in the manual?

Yeastar Technology MyPBX U100 Specifications

General IconGeneral
BrandYeastar Technology
ModelMyPBX U100
CategoryTelephone Accessories
LanguageEnglish