EasyManuals Logo

YOKOGAWA 436106 User Manual

YOKOGAWA 436106
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
ii
IM 04P01B01-17E
Trademarks
All the brands or names of Yokogawa Electric’s products used in this manual are
either trademarks or registered trademarks of Yokogawa Electric Corporation.
Microsoft, MS-DOS, Windows, Windows NT, and Windows XP are either registered
trademarks or trademarks of Microsoft Corporation in the United States and/or other
countries.
Adobe, Acrobat, and PostScript are trademarks of Adobe Systems incorporated.
For purposes of this manual, the TM and ® symbols do not accompany their
respective trademark names or registered trademark names.
Other company and product names are trademarks or registered trademarks of their
respective holders.
Functional Enhancement of the Recorder
The functions of the recorder have been added or changed as shown in the figure below.
You can check the system version on the system display. For details, see the µ
R10000
User’s Manual (IM 04P01B01-01E) or
the µ
R20000 User’s Manual (IM 04P02B01-01E)
.
Version Suffix Code
Sec. 4.4: SA command
Sec. 4.4: TD command
Sec. 4.5: XN command
Sec. 4.5: YS command
Sec. 3.2
Sec. 2.5
Sec. 4.5: UL command
Sec. 4.4: VL commands
Sec. 4.5: UQ and UF commands
Sec. 4.5: UG and UH commands
Sec. 4.4: VH, VC, VP, VA,
VM, and VD commands
Sec. 4.5: UE and XR commands
Sec. 3.4
(Changed) Expanded the selectable range of alarm values
during linear scaling (including 1-5V and SQRT)
to –5% to 105% of the scale.
(Changed) The procedure to set the start/end date and time of
Daylight Saving Time (DST) has been changed.
The TD command can be used on the µR20000 and
the µR10000 with system version 1.11.
The SS command can be used on the µR10000
with system version 1.02 or earlier.
(Added) The print/display format of the date can be changed.
(Changed) Modbus slave protocol can be used.
Two-wire system.
(Changed) Users with the same user name cannot be registered.
(Added) Language support (German and French).
(Added) Calibration Correction.
(Added) Customized menu.
(Added) Header printout.
(Added) Hold registers 40301 to 40348 (floating type register
for communication input data) for Modbus
communication.
1.11
1.21
1.31
/C3
/C7
-2
/CC1
/BT1
µR10000 only
Common to µR10000 and µR20000
ReferenceAdded or Modified Functions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA 436106 and is the answer not in the manual?

YOKOGAWA 436106 Specifications

General IconGeneral
BrandYOKOGAWA
Model436106
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals