4-3
IM 04P01B01-17E
4
Commands
4.2 A List of Commands
Execution Modes and User Levels
Execution Modes
The recorder has two execution modes. Each command is specified to be used in a
particular execution mode. If you attempt to execute a command in a mode that is
different from the specification, a syntax error occurs. Use the DS command to switch to
the appropriate mode, and then execute the command. Query commands can be
executed in either mode.
• Basic Setting mode
Measurement/computation is stopped and settings are changed in this mode.
• Run mode
Run mode
collectively refers to Operation mode and Setting mode of the recorder.
User Levels
The administrator and user specifications in the table indicate the user level that is specified
using the login function for Ethernet communications. For details, see section 1.1.
Setting Commands
Command Function Execution Mode Administrator User Page
Name
SR Sets the input range. Run mode Yes No 4-10
VB Sets the bias. Run mode Yes No 4-11
VL Sets the calibration correction (/CC1 option). Run mode Yes No 4-11
SA Sets the alarm. Run mode Yes No 4-11
SN Sets the unit. Run mode Yes No 4-12
SC Sets the chart speed. Run mode Yes No 4-13
SD Sets the date and time. Run mode Yes No 4-13
VT Sets the dot printing interval (dot model). Run mode Yes No 4-13
SZ Sets zone recording. Run mode Yes No 4-13
SP Sets the partial expanded recording. Run mode Yes No 4-13
VR Turns ON/OFF the recording on each channel. Run mode Yes No 4-14
ST Sets the tag. Run mode Yes No 4-14
SG Sets the message. Run mode Yes No 4-14
SE Sets the secondary chart speed Run mode Yes No 4-14
(used by the remote control function (/R1 option)).
SV Sets the moving average (dot model). Run mode Yes No 4-14
SF Sets the input filter (pen model). Run mode Yes No 4-14
BD Sets the alarm delay time. Run mode Yes No 4-14
VF Sets the brightness of the display (VFD) and internal Run mode Yes No 4-14
illumination.
TD Sets the DST. Run mode Yes No 4-15
SS Sets the DST. (Can be used on the µR10000 with system Run mode Yes No 4-15
version 1.02 or earlier)
SO Sets the computing equation (/M1 option). Run mode Yes No 4-15
SK Sets the computation constant (/M1 option). Run mode Yes No 4-15
SJ Sets the timer used in TLOG computation (/M1 option). Run mode Yes No 4-15
VD Sets the data display screen. Run mode Yes No 4-16
CM Sets the communication input data (/M1 option). Run mode Yes No 4-18
FR Sets the acquiring interval to the FIFO buffer. Run mode Yes No 4-18
VH Sets the batch number and lot number (/BT1 option). Run mode Yes No 4-18
VC Sets the batch comment (/BT1 option). Run mode Yes No 4-18
VP Turns Start printout/End printout ON/OFF (/BT1 option). Run mode Yes No 4-19
VA Sets the Start printout/End printout action (/BT1 option). Run mode Yes No 4-19
VM Sets the message format (/BT1 option). Run mode Yes No 4-19
Yes: Command usable
No: Command not usable