5-61
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
:ANALysis:XY<x>:GATE:ALEVel
Function Sets the active level of the gate of the XY display or
queries the current setting.
Syntax
:ANALysis:XY<x>:GATE:ALEVel {HIGH|LOW}
:ANALysis:XY<x>:GATE:ALEVel?
<x> = 1 or 2
Example
:ANALYSIS:XY1:GATE:ALEVEL HIGH
:ANALYSIS:XY1:GATE:ALEVEL?
-> :ANALYSIS:XY1:GATE:ALEVEL HIGH
:ANALysis:XY<x>:GATE:HYSTeresis<x>
Function Sets the hysteresis of the gate of the XY display or
queries the current setting.
Syntax
:ANALysis:XY<x>:GATE:HYSTeresis<x>
{<NRf>}
:ANALysis:XY<x>:GATE:HYSTeresis<x>?
<x> of XY<x> = 1 or 2
<x> of HYST
eresis<x> = 1 to 8
<NRf> = 0 to 4 (div)
Example
:ANALYSIS:XY1:GATE:HYSTERESIS1 1
:ANALYSIS:XY1:GATE:HYSTERESIS1?
-> :ANALYSIS:XY1:GATE:
HYSTERESIS1 1.000E+00
:ANALysis:XY<x>:GATE:LEVel<x>
Function Sets the level of the gate of the XY display or queries
the current setting.
Syntax
:ANALysis:XY<x>:GATE:LEVel<x> {<NRf>,<V
oltage>,<Current>}
:ANALysis:XY<x>:GATE:LEVel<x>?
<x> of XY<x> = 1 or 2
<x> of LEV
el<x> = 1 to 8
<NRf>, <Voltage>, and <Current> = See the DL9000
User’s Manual.
Example
:ANALYSIS:XY1:GATE:LEVEL1 1
:ANALYSIS:XY1:GATE:LEVEL1?
-> :ANALYSIS:XY1:GATE:LEVEL1 1.000E+00
:ANALysis:XY<x>:GATE:TRACe
Function Sets the gate trace of the XY display or queries the
current setting.
Syntax
:ANALysis:XY<x>:GATE:TRACe {<NRf>|OFF}
:ANALysis:XY<x>:GATE:TRACe?
<x> = 1 or 2
<NRf> = 1 to 8
Example
:ANALYSIS:XY1:GATE:TRACE 1
:ANALYSIS:XY1:GATE:TRACE? -> :ANALYSIS:
XY1:GATE:TRACE 1
:ANALysis:XY<x>:MEASure?
Function Queries all settings related to the automated
measurement of the XY display.
Syntax
:ANALysis:XY<x>:MEASure?
<x> = 1 or 2
Example
:ANALYSIS:XY1:MEASURE? -> :ANALYSIS:
XY1:MEASURE:CURSOR:X1:
POSITION 1.000E+00;:ANALYSIS:XY1:
MEASURE:CURSOR:X2:POSITION 2.000E+00;:
ANALYSIS:XY1:MEASURE:CURSOR:XLINkAGE 1;
Y1:POSITION 1.000E+00;:ANALYSIS:XY1:
MEASURE:CURSOR:Y2:POSITION 2.000E+00;:
ANALYSIS:XY1:MEASURE:CURSOR:
YLINkAGE 1;:ANALYSIS:XY1:MEASURE:
MODE CURSOR;XYINTEG:LOOP CLOSE;
POLARITY CCW
:ANALysis:XY<x>:MEASure:CURSor?
Function Queries all settings related to the cursor
measurement of the XY display.
Syntax
:ANALysis:XY<x>:MEASure:CURSor?
<x> = 1 or 2
Example
:ANALYSIS:XY1:MEASURE:CURSOR?
-> :ANALYSIS:XY1:MEASURE:CURSOR:X1:
POSITION 1.000E+00;:ANALYSIS:XY1:
MEASURE:CURSOR:X2:POSITION 2.000E+00;:
ANALYSIS:XY1:MEASURE:CURSOR:XLINkAGE 1;
Y1:POSITION 1.000E+00;:ANALYSIS:XY1:
MEASURE:CURSOR:Y2:POSITION 2.000E+00;:
ANALYSIS:XY1:MEASURE:CURSOR:YLINkAGE 1
5.3 ANALysis Group

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL9040 and is the answer not in the manual?

YOKOGAWA DL9040 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL9040
CategoryTest Equipment
LanguageEnglish

Related product manuals