EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 201

YOKOGAWA DLM2000 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-168
IM 710105-17E
:SERialbus<x>:DECode[:FORMat]
Function Sets or queries the decode display format of serial
bus signals.
Syntax
:SERialbus<x>:DECode[:FORMat] {BINary
|HEXa|ASCii|SYMBol}
:SERialbus<x>:DECode[:FORMat]?
<x> = 1 to 4 (1 only for 2-channel models)
Example
:SERIALBUS1:DECODE:FORMAT BINARY
:SERIALBUS1:DECODE:FORMAT?
-> :SERIALBUS1:DECODE:FORMAT BINARY
:SERialbus<x>:DECode:SSCMode
Function Sets or queries the decode display of the start/
stop condition of I
2
C serial bus signals.
Syntax
:SERialbus<x>:DECode:SSCMode {<Boolea
n>}
:SERialbus<x>:DECode:SSCMode?
<x> = 1 to 4 (1 only for 2-channel models)
Example
:SERIALBUS1:DECODE:SSCMODE ON
:SERIALBUS1:DECODE:SSCMODE?
-> :SERIALBUS1:DECODE:SSCMODE 1
:SERialbus<x>:DISPlay
Function Sets or queries whether or not serial bus signal
analysis will be performed.
Syntax
:SERialbus<x>:DISPlay {<Boolean>}
:SERialbus<x>:DISPlay?
<x> = 1 to 4 (1 only for 2-channel models)
Example
:SERIALBUS1:DISPLAY ON
:SERIALBUS1:DISPLAY?
-> :SERIALBUS1:DISPLAY 1
:SERialbus<x>:FLEXray?
Function Queries all FLEXRAY bus signal settings.
Syntax
:SERialbus<x>:FLEXray?
<x> = 1 to 4
:SERialbus<x>:FLEXray:ANALyze?
Function Queries all FLEXRAY bus signal settings.
Syntax
:SERialbus<x>:FLEXray:ANALyze?
<x> = 1 to 4
:SERialbus<x>:FLEXray[:ANALyze]:SET
up?
Function Queries all FLEXRAY bus signal analysis settings.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:SET
up?
<x> = 1 to 4
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:BCHannel
Function Sets or queries the channel bus type for FLEXRAY
bus signal analysis.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BCHannel {A|B}
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BCHannel?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BCH
ANNEL A
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BCH
ANNEL?
-> :SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
BCHANNEL A
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:BRATe
Function Sets or queries the FLEXRAY bus signal analysis
bit rate (data transfer rate).
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BRATe {<NRf>}
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BRATe?
<x> = 1 to 4
<NRf> = 2500000, 5000000, or 10000000
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BRA
TE 5000000
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BRA
TE?
-> :SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
BRATE 5000000
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SOURce
Function Sets or queries the source signal for FLEXRAY
bus signal analysis.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:SOURce {<NRf>|MATH<y>}
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:SOURce?
<x> = 1 to 4
<NRf> = 1 to 4
<y> = 1 or 2
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:SOU
RCE 1
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:SOU
RCE?
-> :SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
SOURCE 1
5.24 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Related product manuals