5-168
IM 710105-17E
:SERialbus<x>:DECode[:FORMat]
Function Sets or queries the decode display format of serial
bus signals.
Syntax
:SERialbus<x>:DECode[:FORMat] {BINary
|HEXa|ASCii|SYMBol}
:SERialbus<x>:DECode[:FORMat]?
<x> = 1 to 4 (1 only for 2-channel models)
Example
:SERIALBUS1:DECODE:FORMAT BINARY
:SERIALBUS1:DECODE:FORMAT?
-> :SERIALBUS1:DECODE:FORMAT BINARY
:SERialbus<x>:DECode:SSCMode
Function Sets or queries the decode display of the start/
stop condition of I
2
C serial bus signals.
Syntax
:SERialbus<x>:DECode:SSCMode {<Boolea
n>}
:SERialbus<x>:DECode:SSCMode?
<x> = 1 to 4 (1 only for 2-channel models)
Example
:SERIALBUS1:DECODE:SSCMODE ON
:SERIALBUS1:DECODE:SSCMODE?
-> :SERIALBUS1:DECODE:SSCMODE 1
:SERialbus<x>:DISPlay
Function Sets or queries whether or not serial bus signal
analysis will be performed.
Syntax
:SERialbus<x>:DISPlay {<Boolean>}
:SERialbus<x>:DISPlay?
<x> = 1 to 4 (1 only for 2-channel models)
Example
:SERIALBUS1:DISPLAY ON
:SERIALBUS1:DISPLAY?
-> :SERIALBUS1:DISPLAY 1
:SERialbus<x>:FLEXray?
Function Queries all FLEXRAY bus signal settings.
Syntax
:SERialbus<x>:FLEXray?
<x> = 1 to 4
:SERialbus<x>:FLEXray:ANALyze?
Function Queries all FLEXRAY bus signal settings.
Syntax
:SERialbus<x>:FLEXray:ANALyze?
<x> = 1 to 4
:SERialbus<x>:FLEXray[:ANALyze]:SET
up?
Function Queries all FLEXRAY bus signal analysis settings.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:SET
up?
<x> = 1 to 4
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:BCHannel
Function Sets or queries the channel bus type for FLEXRAY
bus signal analysis.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BCHannel {A|B}
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BCHannel?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BCH
ANNEL A
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BCH
ANNEL?
-> :SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
BCHANNEL A
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:BRATe
Function Sets or queries the FLEXRAY bus signal analysis
bit rate (data transfer rate).
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BRATe {<NRf>}
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:BRATe?
<x> = 1 to 4
<NRf> = 2500000, 5000000, or 10000000
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BRA
TE 5000000
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:BRA
TE?
-> :SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
BRATE 5000000
:SERialbus<x>:FLEXray[:ANALyze]:SETu
p:SOURce
Function Sets or queries the source signal for FLEXRAY
bus signal analysis.
Syntax
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:SOURce {<NRf>|MATH<y>}
:SERialbus<x>:FLEXray[:ANALyze]:
SETup:SOURce?
<x> = 1 to 4
<NRf> = 1 to 4
<y> = 1 or 2
Example
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:SOU
RCE 1
:SERIALBUS1:FLEXRAY:ANALYZE:SETUP:SOU
RCE?
-> :SERIALBUS1:FLEXRAY:ANALYZE:SETUP:
SOURCE 1
5.24 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM2000 Series and is the answer not in the manual?

YOKOGAWA DLM2000 Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals