5-194
IM 710105-17E
:SERialbus<x>:PSI5:TRENd<y>:VERTical
Function Sets or queries the vertical range of the PSI5
signal analysis trend display.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:VERTic
al {<NRf>,<NRf>}
:SERialbus<x>:PSI5:TRENd<y>:VERTical?
<NRf> = 1.0000E+31 to 1.0000E+31
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:PSI5:TREND1:VERTICAL1,−1
:SERIALBUS1:PSI5:TREND1:VERTICAL?
-> :SERIALBUS1:PSI5:TREND1:VERTIC
AL1.0000000E+00,−1.0000000E+00
:SERialbus<x>:PSI5:TRENd<y>:VTDispl
ay
Function Sets or queries the on/off status of the VT
waveform display on the PSI5 signal analysis
trend display.
Syntax
:SERialbus<x>:PSI5:TRENd<y>:VTDispl
ay {<Boolean>}
:SERialbus<x>:PSI5:TRENd<y>:VTDispl
ay?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:PSI5:TREND1:VTDISPLAY ON
:SERIALBUS1:PSI5:TREND1:VTDISPLAY?
-> :SERIALBUS1:PSI5:TREND1:VTDISPLAY
1
:SERialbus<x>:RWINdow
Function Sets or queries in which zoom window, ZOOM1 or
ZOOM2, the detected section will be displayed.
Syntax
:SERialbus<x>:RWINdow {Z1|Z2}
:SERialbus<x>:RWINdow?
<x> = 1 to 4 (1 only for 2-channel models)
Example
:SERIALBUS1:RWINDOW Z1
:SERIALBUS1:RWINDOW?
-> :SERIALBUS1:RWINDOW Z1
:SERialbus<x>:SENT?
Function Queries all SENT signal analysis and search
settings.
Syntax
:SERialbus<x>:SENT?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]?
Function Queries all SENT signal analysis settings.
Syntax
:SERialbus<x>:SENT[:ANALyze]?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup?
Function Queries all bus setup settings for SENT signal
analysis.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:D
ISPlay
Function Sets or queries the display mode for the SENT
signal analysis result.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:DI
SPlay {BOTH|FAST|SLOW}
:SERialbus<x>:SENT[:ANALyze]:SETup:DI
SPlay?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:DISPL
AY BOTH
:SERIALBUS1:SENT:ANALYZE:SETUP:DISPL
AY?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:DIS
PLAY BOTH
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST?
Function Queries all SENT signal analysis fast channel
settings.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:DTYPe
Function Sets or queries the SENT signal analysis fast
channel data format.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:DTYPe {NIBBle|USER}
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:DTYPe?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:D
TYPE NIBBLE
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:D
TYPE?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:FAS
T:DTYPE NIBBLE
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup?
Function Queries all settings related to user-defined data of
the SENT signal analysis fast channel.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:USETup?
<x> = 1 to 4
5.24 SERialbus Group