:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>?
Function Queries all settings related to the specified user-
defined data of the SENT signal analysis fast
channel.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:USETup:DATA<y>?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>:MODE
Function Sets or queries the enable/disable condition of the
specified user-defined data of the SENT signal
analysis fast channel.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:USETup:DATA<y>:MODE {<Boolean>}
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:USETup:DATA<y>:MODE?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:U
SETUP:DATA1:MODE ON
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:U
SETUP:DATA1:MODE?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:FAS
T:USETUP:DATA1:MODE 1
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>:ORDer
Function Sets or queries the byte order of the specified
user-defined data of the SENT signal analysis fast
channel.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:
FAST:USETup:DATA<y>:ORDer {BIG|LITTle
}
:SERialbus<x>:SENT[:ANALyze]:SETup:
FAST:USETup:DATA<y>:ORDer?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:U
SETUP:DATA1:ORDER BIG
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:U
SETUP:DATA1:ORDER?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:FAS
T:USETUP:DATA1:ORDER BIG
:SERialbus<x>:SENT[:ANALyze]:SETup:F
AST:USETup:DATA<y>:SIZE
Function Sets or queries the data size of the specified user-
defined data of the SENT signal analysis fast
channel.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:USETup:DATA<y>:SIZE {<NRf>}
:SERialbus<x>:SENT[:ANALyze]:SETup:FA
ST:USETup:DATA<y>:SIZE?
<x> = 1 to 4
<y> = 1 to 4
<NRf> = 0 to 24
Example
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:U
SETUP:DATA1:SIZE 24
:SERIALBUS1:SENT:ANALYZE:SETUP:FAST:U
SETUP:DATA1:SIZE?
-> :SERIALBUS1:SENT:ANALYZE:SETUP:FAS
T:USETUP:DATA1:SIZE 24
:SERialbus<x>:SENT[:ANALyze]:SETup:F
ORMat?
Function Queries all SENT signal analysis format settings.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FO
RMat?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
ORMat:CEFactor?
Function Queries all SENT signal analysis error factor
settings.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FO
RMat:CEFactor?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
ORMat:CEFactor:SAComm?
Function Queries all status and communication error factor
settings of SENT signal analysis.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FO
RMat:SAComm?
<x> = 1 to 4
:SERialbus<x>:SENT[:ANALyze]:SETup:F
ORMat:CEFactor:SAComm:BIT<y>?
Function Queries all status and communication error factor
bit settings of SENT signal analysis.
Syntax
:SERialbus<x>:SENT[:ANALyze]:SETup:FO
RMat:SAComm:BIT<y>?
<x> = 1 to 4
<y> = 0, 1
5.24 SERialbus Group