EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 250

YOKOGAWA DLM2000 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-217
IM 710105-17E
Commands
1
2
3
4
5
6
App
Index
:SERialbus<x>:SPI:SEARch[:SETup]:DAT
A<y>:CONDition
Function Sets or queries the data comparison condition (true
or false) for SPI bus signal searching.
Syntax
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:CONDition {FALSe|TRUE}
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:CONDition?
<x> = 1 to 4
<y> = 1 or 2
Example
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:CO
NDITION DONTCARE
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:CO
NDITION?
-> :SERIALBUS1:SPI:SEARCH:SETUP:
DATA1:CONDITION DONTCARE
:SERialbus<x>:SPI:SEARch[:SETup]:DAT
A<y>:DBYTe
Function Sets or queries the data size (in bytes) for SPI bus
signal searching.
Syntax
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:DBYTe {<NRf>}
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:DBYTe?
<x> = 1 to 4
<y> = 1 or 2
<NRf> = 1 to 4
Example
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:DB
YTE 1
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:DB
YTE?
-> :SERIALBUS1:SPI:SEARCH:SETUP:
DATA1:DBYTE 1
:SERialbus<x>:SPI:SEARch[:SETup]:DAT
A<y>:HEXa<z>
Function Sets the data for SPI bus signal searching in
hexadecimal notation.
Syntax
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:HEXa<z> {<String>}
<x> = 1 to 4
<y> = 1 or 2
<z> = 1 to 4
Example
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:HE
XA1 "AB"
:SERialbus<x>:SPI:SEARch[:SETup]:DAT
A<y>:MODE
Function Sets or queries the data enable/disable condition
for SPI bus signal searching.
Syntax
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:MODE {<Boolean>}
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:MODE?
<x> = 1 to 4
<y> = 1 or 2
Example
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:MO
DE ON
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:MO
DE?
-> :SERIALBUS1:SPI:SEARCH:SETUP:
DATA1:MODE 1
:SERialbus<x>:SPI:SEARch[:SETup]:DAT
A<y>:PATTern<z>
Function Sets or queries the data value for SPI bus signal
searching in binary notation.
Syntax
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:PATTern<z> {<String>}
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:PATTern<z>?
<x> = 1 to 4
<y> = 1 or 2
<z> = 1 to 4
Example
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:PA
TTERN1 "11001010"
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:PA
TTERN1?
-> :SERIALBUS1:SPI:SEARCH:SETUP:DATA1
:PATTERN1 "11001010"
:SERialbus<x>:SPI:SEARch[:SETup]:DAT
A<y>:PFORmat
Function Sets or queries the input format, which is one of
the data conditions, for SPI bus signal searching.
Syntax
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:PFORmat {BINary|HEXa}
:SERialbus<x>:SPI:SEARch[:SETup]:DATA
<y>:PFORmat?
<x> = 1 to 4
<y> = 1 or 2
Example
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:PF
ORMAT BINARY
:SERIALBUS1:SPI:SEARCH:SETUP:DATA1:PF
ORMAT?
-> :SERIALBUS1:SPI:SEARCH:SETUP:
DATA1:PFORMAT BINARY
5.24 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series