EasyManua.ls Logo

YOKOGAWA DLM2000 Series - Page 296

YOKOGAWA DLM2000 Series
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-263
IM 710105-17E
Commands
1
2
3
4
5
6
App
Index
:TRIGger{[:ATRigger]|:BTRigger}:SPI:
DATA<x>:BCOunt
Function Sets or queries the starting position of data
comparison for SPI bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:BCOunt {<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:BCOunt?
<x> = 1 or 2
<NRf> = 0 to 9999
Example
:TRIGGER:ATRIGGER:SPI:DATA1:BCOUNT 0
:TRIGGER:ATRIGGER:SPI:DATA1:BCOUNT?
-> :TRIGGER:ATRIGGER:SPI:DATA1:BCOU
NT 0
:TRIGger{[:ATRigger]|:BTRigger}:SPI:
DATA<x>:CONDition
Function Sets or queries the data comparison condition (true
or false) for SPI bus signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:CONDition {FALSe|TRUE}
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:CONDition?
<x> = 1 or 2
Example
:TRIGGER:ATRIGGER:SPI:DATA1:CONDITI
ON FALSE
:TRIGGER:ATRIGGER:SPI:DATA1:CONDITI
ON?
-> :TRIGGER:ATRIGGER:SPI:DATA1:CONDIT
ION FALSE
:TRIGger{[:ATRigger]|:BTRigger}:SPI:
DATA<x>:DBYTe
Function Sets or queries the data size (in bytes) for SPI bus
signal triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:DBYTe {<NRf>}
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:DBYTe?
<x> = 1 or 2
<NRf> = 1 to 4
Example
:TRIGGER:ATRIGGER:SPI:DATA1:DBYTE 1
:TRIGGER:ATRIGGER:SPI:DATA1:DBYTE?
-> :TRIGGER:ATRIGGER:SPI:DATA1:
DBYTE 1
:TRIGger{[:ATRigger]|:BTRigger}:SPI:
DATA<x>:HEXa<y>
Function Sets a data value for SPI bus signal triggering in
hexadecimal notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:HEXa<y> {<String>}
<x> = 1 or 2
<y> = 1 to 4
Example
:TRIGGER:ATRIGGER:SPI:DATA1:
HEXA1 "AB"
:TRIGger{[:ATRigger]|:BTRigger}:SPI:
DATA<x>:MODE
Function Sets or queries the data enable/disable condition
for SPI bus signal triggering (on/off).
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:MODE {<Boolean>}
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:MODE?
<x> = 1 or 2
Example
:TRIGGER:ATRIGGER:SPI:DATA1:MODE ON
:TRIGGER:ATRIGGER:SPI:DATA1:MODE?
-> :TRIGGER:ATRIGGER:SPI:DATA1:MODE 1
:TRIGger{[:ATRigger]|:BTRigger}:SPI:
DATA<x>:PATTern<y>
Function Sets or queries the data value for SPI bus signal
triggering in binary notation.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:PATTern<y> {<String>}
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:PATTern<y>?
<x> = 1 or 2
<y> = 1 to 4
Example
:TRIGGER:ATRIGGER:SPI:DATA1:PATTE
RN1 "11001010"
:TRIGGER:ATRIGGER:SPI:DATA1:PATTERN1?
-> :TRIGGER:ATRIGGER:SPI:DATA1:PATTE
RN1 "11001010"
:TRIGger{[:ATRigger]|:BTRigger}:SPI:
DATA<x>:PFORmat
Function Sets or queries the data input format, which is
one of the data conditions, for SPI bus signal
triggering.
Syntax
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:PFORmat {BINary|HEXa}
:TRIGger{[:ATRigger]|:BTRigger}:SPI:D
ATA<x>:PFORmat?
<x> = 1 or 2
Example
:TRIGGER:ATRIGGER:SPI:DATA1:PFORM
AT BINARY
:TRIGGER:ATRIGGER:SPI:DATA1:PFORMAT?
-> :TRIGGER:ATRIGGER:SPI:DATA1:PFORM
AT BINARY
5.33 TRIGger Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series