:TRIGger:MODE
Function Sets or queries the trigger mode.
Syntax
:TRIGger:MODE {AUTO|ALEVel|NORMal|NSI
Ngle}
:TRIGger:MODE?
Example
:TRIGGER:MODE AUTO
:TRIGGER:MODE?
-> :TRIGGER:MODE AUTO
Description You can set or query the count for “NSINgle” by
using
:TRIGger:SCOunt
.
:TRIGger:POSition
Function Sets or queries the trigger position.
Syntax
:TRIGger:POSition {<NRf>}
:TRIGger:POSition?
<NRf> = 0 to 100% in 0.1% steps
Example
:TRIGGER:POSITION 50
:TRIGGER:POSITION?
-> :TRIGGER:POSITION 50.000
:TRIGger:SCOunt
Function Sets or queries the number of times the trigger
condition must be met when the trigger mode is
set to Single(N).
Syntax
:TRIGger:SCOunt {<NRf>}
:TRIGger:SCOunt?
<NRf> = 1 to 20000
Example
:TRIGGER:SCOUNT 100
:TRIGGER:SCOUNT?
-> :TRIGGER:SCOUNT 100
:TRIGger:SOURce?
Function Queries all trigger source settings for enhanced
triggering.
Syntax
:TRIGger:SOURce?
:TRIGger:SOURce:CHANnel<x>?
Function Queries all of the settings of the specified trigger
source for enhanced triggering.
Syntax
:TRIGger:SOURce:CHANnel<x>?
<x> = 1 to 4 (1 or 2 for 2-channel models)
:TRIGger:SOURce:CHANnel<x>:COUPling
Function Sets or queries the specified trigger source trigger
coupling for enhanced triggering.
Syntax
:TRIGger:SOURce:CHANnel<x>:COUPli
ng {AC|DC}
:TRIGger:SOURce:CHANnel<x>:COUPling?
<x> = 1 to 4 (1 or 2 for 2-channel models)
Example
:TRIGGER:SOURCE:CHANNEL1:COUPLING AC
:TRIGGER:SOURCE:CHANNEL1:COUPLING?
-> :TRIGGER:SOURCE:CHANNEL1:
COUPLING AC
:TRIGger:SOURce:CHANnel<x>:HFRejecti
on (HighFrequencyREJECTION)
Function Sets or queries the low-pass filter setting of the
specified trigger source for enhanced triggering.
Syntax
:TRIGger:SOURce:CHANnel<x>:HFRejecti
on {<Frequency>|OFF}
:TRIGger:SOURce:CHANnel<x>:HFRejecti
on?
<x> = 1 to 4 (1 or 2 for 2-channel models)
<Frequency> = 15 kHz to 20MHz
Example
:TRIGGER:SOURCE:CHANNEL1:HFREJECTI
ON 15KHZ
:TRIGGER:SOURCE:CHANNEL1:HFREJECTION?
-> :TRIGGER:SOURCE:CHANNEL1:HFREJECTI
ON 15000
:TRIGger:SOURce:CHANnel<x>:HYSTeres
is
Function Sets or queries the noise rejection setting of the
specified trigger source for enhanced triggering.
Syntax
:TRIGger:SOURce:CHANnel<x>:HYSTeres
is {HIGH|LOW}
:TRIGger:SOURce:CHANnel<x>:HYSTeres
is?
<x> = 1 to 4 (1 or 2 for 2-channel models)
Example
:TRIGGER:SOURCE:CHANNEL1:HYSTERES
IS HIGH
:TRIGGER:SOURCE:CHANNEL1:HYSTERESIS?
-> :TRIGGER:SOURCE:CHANNEL1:HYSTERES
IS HIGH
:TRIGger:SOURce:CHANnel<x>:LEVel
Function Sets or queries the trigger level of the specified
trigger source for enhanced triggering.
Syntax
:TRIGger:SOURce:CHANnel<x>:LEV
el {<Voltage>}
:TRIGger:SOURce:CHANnel<x>:LEVel?
<x> = 1 to 4 (1 or 2 for 2-channel models)
<Voltage> = See the DLM2000 Features Guide for
this information.
Example
:TRIGGER:SOURCE:CHANNEL1:LEVEL 0V
:TRIGGER:SOURCE:CHANNEL1:LEVEL?
-> :TRIGGER:SOURCE:CHANNEL1:LEVEL 0.0
00E+00
Description When the probe type is set to current, this
command sets or queries the <Current> value.
5.33 TRIGger Group

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM2000 Series and is the answer not in the manual?

YOKOGAWA DLM2000 Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals