Appendix
App-3
IM 710105-17E
1
2
3
4
5
6
App
Index
Code Message Corrective Action Page
151 Invalid string data. The parameter is either too long, or it contains an
unusable character.
4-7 and
chapter 5
158 String data not allowed. Use a data type other than <String data>. 4-6 and
chapter 5
161 Invalid block data. <Block data> cannot be used. 4-7 and
chapter 5
168 Block data not allowed. <Block data> cannot be used. 4-7 and
chapter 5
171 Missing Right. Mathematical operations cannot be used.
172 Invalid expression. Mathematical operations cannot be used. Chapter 5
178 Expression data not allowed. Mathematical operations cannot be used. Chapter 5
181 Invalid outside macro definition. The DLM2000 does not support the IEEE488.2 macro
specifications.
Communication Execution Errors (200 to 299)
Code Message Corrective Action Page
221 Setting conflict. Check settings that are related to each other. Chapter 5
222 Data out of range. Check the ranges of the settings. Chapter 5
223 Too much data. Check data byte lengths. Chapter 5
224 Illegal parameter value. Check the ranges of the settings. Chapter 5
225 OverFlow. Keep program messages to 1024 bytes or less in
length, including <PMT>.
4-2
226 Out Of Memory. Keep program messages to 1024 bytes or less in
length, including <PMT>.
4-2
241 Hardware missing. Check that the specified options are all installed.
260 Expression error. Mathematical operations cannot be used.
270 Macro error. The DLM2000 does not support the IEEE488.2 macro
specifications.
272 Macro execution error. The DLM2000 does not support the IEEE488.2 macro
specifications.
273 Illegal macro label. The DLM2000 does not support the IEEE488.2 macro
specifications.
275 Macro definition too long. The DLM2000 does not support the IEEE488.2 macro
specifications.
276 Macro recursion error. The DLM2000 does not support the IEEE488.2 macro
specifications.
277 Macro redefinition not allowed. The DLM2000 does not support the IEEE488.2 macro
specifications.
278 Macro header not found. The DLM2000 does not support the IEEE488.2 macro
specifications.
Appendix 2 Error Messages

Table of Contents

Other manuals for YOKOGAWA DLM2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM2000 Series and is the answer not in the manual?

YOKOGAWA DLM2000 Series Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals