:SERialbus<x>:FLEXray:SEARch:FJUMp:C
COunt
Function Jumps to the cycle-count field in the FlexRay bus
signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:C
COunt
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:CCO
UNT
:SERialbus<x>:FLEXray:SEARch:FJUMp:C
RC
Function Jumps to the CRC Field in the FlexRay bus signal
analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:C
RC
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:CRC
:SERialbus<x>:FLEXray:SEARch:FJUMp:F
RAMeid
Function Jumps to the frame ID field in the FlexRay bus
signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:F
RAMeid
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:FRA
MEID
:SERialbus<x>:FLEXray:SEARch:FJUMp:H
CRC
Function Jumps to the Header CRC Field in the FlexRay
bus signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:H
CRC
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:HC
RC
:SERialbus<x>:FLEXray:SEARch:FJUMp:P
LENgth
Function Jumps to the Payload Length Field in the FlexRay
bus signal analysis results.
Syntax
:SERialbus<x>:FLEXray:SEARch:FJUMp:P
LENgth
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:FJUMP:PLE
NGTH
:SERialbus<x>:FLEXray:SEARch:SELect
Function Sets the detected-waveform number of the
FlexRay bus signal search, or queries the zoom
location that corresponds to the number.
Syntax
:SERialbus<x>:FLEXray:SEARch:SELe
ct {<NRf>|MAXimum}
:SERialbus<x>:FLEXray:SEARch:SELect?
<x> = 1 to 4
<NRf> = 0 to 49999
Example
:SERIALBUS1:FLEXRAY:SEARCH:SELECT 1
:SERIALBUS1:FLEXRAY:SEARCH:SELECT?
-> :SERIALBUS1:FLEXRAY:SEARCH:SELEC
T 1.50000000
:SERialbus<x>:FLEXray:SEARch:SETup?
Function Queries all FlexRay bus signal search condition
settings.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup?
<x> = 1 to 4
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor?
Function Queries all FlexRay bus signal search error
settings.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor?
<x> = 1 to 4
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:BSS
Function Sets or queries the FlexRay bus signal search
BSS error setting.
Syntax
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:BSS {<Boolean>}
:SERialbus<x>:FLEXray:SEARch:SETup:E
RRor:BSS?
<x> = 1 to 4
Example
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERR
OR:BSS ON
:SERIALBUS1:FLEXRAY:SEARCH:SETUP:ERR
OR:BSS?
-> :SERIALBUS1:FLEXRAY:SEARCH:SETUP:
ERROR:BSS 1
5.25 SERialbus Group

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals