EasyManuals Logo

YOKOGAWA DLM4038 User Manual

YOKOGAWA DLM4038
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #350 background imageLoading...
Page #350 background image
5-317
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
5.37 XY Group
:XY<x>:MEASure:CURSor:DY?
Function Queries all settings for the voltage difference
between the XY display’s vertical cursors.
Syntax
:XY<x>:MEASure:CURSor:DY?
<x> = 1 to 4
:XY<x>:MEASure:CURSor:DY:STATe
Function Sets or queries the on/off status of the voltage
difference between the XY display’s vertical
cursors.
Syntax
:XY<x>:MEASure:CURSor:DY:STATe {<Boo
lean>}
:XY<x>:MEASure:CURSor:DY:STATe?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DY:STATE ON
:XY1:MEASURE:CURSOR:DY:STATE?
-> :XY1:MEASURE:CURSOR:DY:STATE 1
:XY<x>:MEASure:CURSor:DY:VALue?
Function Queries the voltage difference between theXY
display’s vertical cursors.
Syntax
:XY<x>:MEASure:CURSor:DY:VALue?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DY:VALUE?
-> :XY1:MEASURE:CURSOR:DY:VALUE 6.00
0E+00
:XY<x>:MEASure:CURSor:X<y>?
Function Queries all horizontal cursor settings for the XY
display.
Syntax
:XY<x>:MEASure:CURSor:X<y>?
<x> = 1 to 4
<y> = 1 to 2
:XY<x>:MEASure:CURSor:X<y>:POSition
Function Sets or queries a horizontal cursor position in the
XY display.
Syntax
:XY<x>:MEASure:CURSor:X<y>:POSiti
on {<NRf>}
:XY<x>:MEASure:CURSor:X<y>:POSition?
<x> = 1 to 4
<y> = 1 to 2
<NRf> = −4 to 4 (div)
Example
:XY1:MEASURE:CURSOR:X1:POSITION 1
:XY1:MEASURE:CURSOR:X1:POSITION?
-> :XY1:MEASURE:CURSOR:X1:POSITION 1
.000E+00
:XY<x>?
Function Queries all XY display settings.
Syntax
:XY<x>?
<x> = 1 to 4
:XY<x>:DISPlay
Function Sets or queries the on/off status of the XY display.
Syntax
:XY<x>:DISPlay {<Boolean>}
:XY<x>:DISPlay?
<x> = 1 to 2
Example
:XY1:DISPLAY ON
:XY1:DISPLAY?
-> :XY1:DISPLAY 1
:XY<x>:MEASure?
Function Queries all automated measurement settings for
the XY display.
Syntax
:XY<x>:MEASure?
<x> = 1 to 4
:XY<x>:MEASure:CURSor?
Function Queries all cursor measurement settings for the
XY display.
Syntax
:XY<x>:MEASure:CURSor?
<x> = 1 to 4
:XY<x>:MEASure:CURSor:DX?
Function Queries all settings for the voltage difference
between theXY display’s horizontal cursors.
Syntax
:XY<x>:MEASure:CURSor:DX?
<x> = 1 to 4
:XY<x>:MEASure:CURSor:DX:STATe
Function Sets or queries the on/off status of the voltage
difference between theXY display’s horizontal
cursors.
Syntax
:XY<x>:MEASure:CURSor:DX:STATe {<Boo
lean>}
:XY<x>:MEASure:CURSor:DX:STATe?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DX:STATE ON
:XY1:MEASURE:CURSOR:DX:STATE?
-> :XY1:MEASURE:CURSOR:DX:STATE 1
:XY<x>:MEASure:CURSor:DX:VALue?
Function Queries the voltage difference between theXY
display’s horizontal cursors.
Syntax
:XY<x>:MEASure:CURSor:DX:VALue?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DX:VALUE?
-> :XY1:MEASURE:CURSOR:DX:VALUE 6.00
0E+00

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals