5.36 WPARameter Group
:WPARameter<x>?
Function Queries all of the settings for the waveform
parameter measurement feature.
Syntax
:WPARameter<x>?
<x> = 1 to 2
:WPARameter<x>:DISPlay
Function Sets or queries the on/off status of waveform
parameter measurement display.
Syntax
:WPARameter<x>:DISPlay {<Boolean>}
:WPARameter<x>:DISPlay?
<x> = 1 to 2
Example
:WPARAMETER1:DISPLAY ON
:WPARAMETER1:DISPLAY?
-> :WPARAMETER1:DISPLAY 1
:WPARameter<x>:HISTogram?
Function Queries all histogram display settings for
waveform parameter measurement.
Syntax
:WPARameter<x>:HISTogram?
<x> = 1 to 2
:WPARameter<x>:HISTogram:MEASure?
Function Queries all automatic measurement settings of
the histogram display for waveform parameter
measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure?
<x> = 1 to 2
:WPARameter<x>:HISTogram:MEASure:MO
DE
Function Sets or queries the automatic measurement
mode of the histogram display for waveform
parameter measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure:MO
DE {OFF|PARameter}
:WPARameter<x>:HISTogram:MEASure:MO
DE?
<x> = 1 to 2
Example
:WPARAMETER1:HISTOGRAM:MEASURE:MO
DE OFF
:WPARAMETER1:HISTOGRAM:MEASURE:MODE?
-> :WPARAMETER1:HISTOGRAM:MEASURE:MO
DE OFF
:WPARameter<x>:HISTogram:MEASure:PAR
ameter?
Function Queries all automatic measurement settings of
the histogram parameter for waveform parameter
measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure:PAR
ameter?
<x> = 1 to 2
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:ALL
Function Collectively turns on or off all histogram
parameters for waveform parameter
measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:ALL {<Boolean>}
<x> = 1 to 2
Example
:WPARAMETER1:HISTOGRAM:MEASURE:PARAM
ETER:ALL ON
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:<Parameter>?
Function Queries all of the settings of a histogram
parameter for waveform parameter measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:<Parameter>?
<x> = 1 to 2
<Parameter> =
{C1|C2|DC|MAXimum|MEAN|
MEDian|MINimum|PEAK|SD2integ|
SD3integ|SDEViation|SDINteg}
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:<Parameter>:STATe
Function Sets or queries the on/off status of a histogram
parameter for waveform parameter measurement.
Syntax
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:<Parameter>:STATe {<Boolean>}
:WPARameter<x>:HISTogram:MEASure:PAR
ameter:<Parameter>:STATe?
<x> = 1 to 2
<Parameter> =
{C1|C2|DC|MAXimum|MEAN|
MEDian|MINimum|PEAK|SD2integ|
SD3integ|SDEViation|SDINteg}
Example Below are examples for the maximum
:WPARAMETER1:HISTOGRAM:MEASURE:PARAM
ETER:MAXIMUM:STATE ON
:WPARAMETER1:HISTOGRAM:MEASURE:PARAM
ETER:MAXIMUM:STATE?
-> :WPARAMETER1:HISTOGRAM:MEASURE:PA
RAMETER:MAXIMUM:STATE 1

Table of Contents

Other manuals for YOKOGAWA DLM4038

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DLM4038 and is the answer not in the manual?

YOKOGAWA DLM4038 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDLM4038
CategoryTest Equipment
LanguageEnglish

Related product manuals